Dell E11J001 owner manual Replacing Cooling Fan Modules, Identifying the Failed Cooling Fan Module

Models: E11J001

1 45
Download 45 pages 47.63 Kb
Page 25
Image 25
Replacing Cooling Fan Modules

NOTE: Allow several seconds for the storage system to recognize the PSU and determine its status. When the PSU is functioning properly, the Power OK indicator turns green and the PSU fault and AC fault indicators are off.

8.In the Dell Storage Client, make sure that the replacement PSU is recognized and shown as up and running.

Next steps

1.Use SupportAssist to send diagnostic data to Dell Technical Support Services.

2.Contact Dell Technical Support Services to let them know that you completed a repair.

Replacing Cooling Fan Modules

The SCv2080 storage system supports five cooling fan modules. If one cooling fan module fails, the remaining fan modules continue to cool the storage system.

NOTE: When a cooling fan module fails, the fan speed in the remaining modules increases significantly to provide adequate cooling. The fan speed decreases gradually when a new cooling fan module is installed.

Identifying the Failed Cooling Fan Module

To determine which cooling fan module failed, use the Dell Storage Client.

1.Click the Hardware tab.

2.In the Hardware tab navigation pane, select the Storage Center.

3.In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed cooling fan.

Figure 15. Hardware Alert Identifying the Enclosure with the Failed Cooling Fan

4.In the Hardware tab navigation pane, expand the enclosure identified in the previous step.

5.Select Cooling Fans. The status of each cooling fan is displayed in the Cooling Fans tab.

Replacing SCv2080 Components

25

Page 25
Image 25
Dell E11J001 owner manual Replacing Cooling Fan Modules, Identifying the Failed Cooling Fan Module