Power Supplies
Maximum inrush current | Under typical line conditions and over the entire system ambient operating |
| range, the inrush current may reach 55 A per power supply for 10 ms or less |
| |
Available Hard Drive Power (per Slot) | |
|
|
Supported hard drive | Up to 1.16 A at +5 V |
power consumption | Up to 1.6 A at +12 V |
(continuous) |
|
|
|
I/O Card Power (per Slot) |
|
|
|
Maximum power | 11 W at +12 V |
consumed by I/O Card |
|
Maximum available | 100 W at +12 V |
power |
|
Minimum available | 1 W at +5 V (standby) |
power |
|
|
|
Physical |
|
|
|
Height | 22.23 cm (8.75 inches) |
Width | 48.26 cm (19 inches) |
Depth | 96 cm (38 inches) |
Weight (maximum | 130 kg (287 lb) |
configuration) |
|
Weight without drives | 62 kg (137 lb) |
Environmental
For additional information about environmental measurements for specific storage system configurations, see dell.com/environmental_datasheets.
Temperature |
|
Operating | 5° to 35°C (41° to 95°F) with a maximum temperature gradation of 10°C per |
| hour |
| NOTE: Maximum 35°C up to 2134 m (7000 ft), derate to 30°C for 2134 m |
| to 3000 m (7000 ft to 10,000 ft) |
Storage | |
| per hour |
Relative humidity |
|
Operating | 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per |
| hour |
Storage | 5% to 100% (noncondensing) |
44 | SCv2080 Technical Specifications |