Dell E18S001, R420 Installing The Power Distribution Board, Removing The System Board

Models: E18S E18S001 R420

1 145
Download 145 pages 41.96 Kb
Page 101
Image 101

1.

screws (2)

5.

power distribution board

2.

power supply cables to the system board (3)

6.

fan cable connector

3.power supply cable to the hard-drive backplane

4.standoffs (2)

Installing The Power Distribution Board

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1.Align the power distribution board with the standoffs on the chassis.

2.Install the two screws that secure the power distribution board to the chassis.

3.Connect the power distribution cables to the system board and fan cable connector to the power distribution board.

4.Install the PDB shroud.

5.Close the system.

6.Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

System Board

Removing The System Board

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

CAUTION: If you are using the Trusted Program Module (TPM) with an encryption key, you may be prompted to create a recovery key during program or System Setup. Be sure to create and safely store this recovery key. If you replace this system board, you must supply the recovery key when you restart your system or program before you can access the encrypted data on your hard drives.

1.Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2.If installed, remove the front bezel.

3.Open the system.

4.Remove the following:

a)cooling shroud

b)PDB shroud

c)memory modules

d)expansion cards and the expansion-card risers

e)integrated storage controller card

WARNING: The heat sink and processor are hot to the touch for some time after the system has been powered down. Allow the heat sink and processor to cool before handling them.

f)heat sink/heat-sink blank and processor/processor blank

g)integrated storage controller card

101

Page 101
Image 101
Dell E18S001, R420 owner manual Installing The Power Distribution Board, Removing The System Board