DeLonghi DE30WGB, DE302GB manual Installation, Electrical Requirements

Models: DE302GB DE30WGB

1 28
Download 28 pages 42.86 Kb
Page 4
Image 4
INSTALLATION

INSTALLATION

CAUTION:

This appliance must be installed in accordance with these installation instructions, local gas fitting regulations, municipal building codes,

water supply regulations, electrical wiring regulations, AS5601 / NZS5261

- Gas Installations and ony other relevant statutory regulations.

This appliance shall be only be serviced by authorized personnel.

This appliance is to be installed only by an authorised person.

Incorrect installation, for which the manufacturer accepts no responsibility, may cause personal injury of damage.

Always disconnect the appliance from mains power supply before carrying out any maintenance operations or repairs.

In the room where the appliance is installed, there must be enough air to allow the gas to burn correctly, according to the current local regulations.

ELECTRICAL REQUIREMENTS

The appliance must be connected to the mains checking that the voltage corresponds to the value given in the rating plate and that the electrical cable sections can withstand the load specified on the plate.

The plug must be connected to an earthed socket in compliance with safety standards.

If the appliance is supplied without plug, fit a standard plug which is suitable for the power consumed by the appliance.

The wires in the power cable are coloured in accordance with the following code: Green/Yellow = Earth, Blue = Neutral, Brown = Active.

If the colours of the wires in the power cable to the appliance do not correspond with the coloured markings identifying the terminals in the junction terminal, proceed as follows:

1.The wire which is coloured green and yellow must be connected to the terminal marked E (Earth) or coloured Green.

2.The wire which is coloured blue must be connected to the terminal marked N (Nuetral) or coloured Black.

3.The wire which is coloured brown must be connected to the terminal marked L (Live) or A (Active) or coloured Red.

A suitable isolating switch providing full disconnection from the mains power supply (under overvoltage category III conditions) shall be incorporated in the permanent wiring, mounted and positioned to comply with the local wiring rules and regulations. The isolating switch must be of an approved type and provide a 3 mm air gap contact separation in all poles (or in all active [phase] conductors if the local wiring rules allow for this variation of the requirements).

The power supply cable must not touch the hot parts and must be positioned so that it does not exceed 50°C above ambient.

Once the appliance has been installed, the switch or socket must always be accessible.

4If the supply cord is damaged it must be replaced by the manufacturer or it’s Service Agent or a similarly qualified person in order to avoid a hazard.