Setting up a measurement session

Working through the menu options

In normal use the SunData software calculates Leaf Area Index (LAI) based on readings from the SunScan probe and from the Beam Fraction Sensor (if fitted). These calculations also require information about the distribution of leaf angles and absorption of light by leaves within the canopy and knowledge of the solar angle calculated from the time of day and local latitude and longitude.

SunScan probe

 

 

Average PAR within canopy

 

 

Beam fraction

 

 

PAR above canopy

ï

 

 

 

 

 

 

 

 

Ratio of Direct to Total light

ï

 

ELADP setting

 

 

 

Leaf Angle Distribution

ï

Leaf Area Index

 

 

 

Absorption setting

 

 

Leaf PAR Absorption

 

Time and date

ü

 

ï

 

Latitude setting

 

 

Solar zenith angle

 

 

Longitude setting

 

 

 

 

 

Before it can make sensible calculations of the Leaf Area Index, SunData needs to know what values to use for the above settings.

♦ Press Menu, use the ← → arrow keys to select the Settings menu, and the ↑↓↓ keys to highlight Site, and press Enter. Type in a Name for your present site, and set the Latitude and Longitude by pressing Del and typing in the appropriate values. When everything is correct, to accept it

♦ Press Menu again, then select Time & Date and press Enter. Now set the local time and date in the dialog box. You also need to set the appropriate offset from GMT for your time zone. Set Local time is GMT to between -12.0 and +13.0 hours. Remember to make allowance for any special seasonal offsets, such as “Summer Time”, “Daylight Saving”. For example: British Summer Time is GMT+1, India is GMT+5.5, and USA EST is GMT - 5.0.

Press Enter to accept the settings and return to the Title screen.

Note: The date and time formats can be changed, but for the moment just get the information correct. To change am to pm, select it, and press p (or a).

♦ Use the ← → arrow keys to set the Absorption to 0.85. Set the ELADP (Ellipsoidal Leaf Angle Distribution Parameter) to 1. Press Enter to accept these settings.

Later sections in Measurement Options and LAI Theory give explanations and advice on choosing values for these parameters.

♦ Set the Display format to LAI. Leave the ‘Sample’ and ‘Plot’ names unchanged.

The options for Display (LAI, PAR and All) have an important effect on the display of readings but they also interact with the setting for Ext sensor (BFS or none) to determine the sequence of readings required.

18 SunScan Tutorial

Document code: SS1-UM-1.05

Page 18
Image 18
Delta Electronics SS1-UM-1.05 user manual Setting up a measurement session, Working through the menu options

SS1-UM-1.05 specifications

Delta Electronics has long been recognized for its innovative solutions in power and thermal management technologies. One of its notable products is the SS1-UM-1.05, a compact and efficient power supply module designed to meet the needs of a variety of applications, from industrial automation to telecommunications.

The Delta SS1-UM-1.05 is a key component in the company’s extensive portfolio, providing reliable and stable power supply for both demanding and sensitive electronic equipment. One of the main features of this module is its high efficiency, which typically exceeds 90%. This not only minimizes energy consumption but also reduces heat generation, making it an ideal choice for applications where thermal management is crucial.

Another significant characteristic of the SS1-UM-1.05 is its wide input voltage range, which allows it to operate effectively in various environments. The module supports a voltage range from 90 to 264 VAC, ensuring consistent performance even in fluctuating supply conditions. This versatility makes it well-suited for global applications, accommodating different electrical standards and requirements.

The SS1-UM-1.05 also boasts a compact footprint, which is essential for space-constrained installations. Its design emphasizes not only performance but also ease of integration into existing systems. The module provides multiple output voltage options, allowing it to cater to specific power requirements, whether it be for industrial machinery or consumer electronics.

In terms of technologies, the SS1-UM-1.05 incorporates advanced power conversion technologies that enhance its overall performance. It features overload protection and thermal shutdown mechanisms to safeguard both the module and the equipment it powers from potential damages due to electrical faults. Moreover, it has low electromagnetic interference (EMI) emissions, which is crucial for environments sensitive to electrical noise.

The SS1-UM-1.05 is also designed with a robust enclosure that adheres to stringent safety and environmental standards. This enhances its durability and reliability, ensuring it can withstand harsh operating conditions. With these features, Delta Electronics demonstrates its commitment to delivering high-quality products that meet the evolving needs of industries worldwide.

Overall, the Delta SS1-UM-1.05 power supply module is an exemplary solution for those seeking a reliable, efficient, and compact power source. Its advanced features and technologies make it an indispensable component in modern electronic systems.