Delta Electronics SS1-UM-1.05 user manual Logging the Beam Fraction sensor

Models: SS1-UM-1.05

1 86
Download 86 pages 51.13 Kb
Page 75
Image 75

B. Logging the Beam Fraction sensor

You can log the Beam Fraction sensor in a similar manner, using the (optional) special logging cable for it. Two outputs are available, corresponding to the Total incident PAR and Diffuse PAR photodiode readings.

Be aware that the shade ring elevation may need readjustment after an hour or two. Also, that separately logged incident PAR readings cannot at present be merged with probe readings of transmitted PAR to give LAI estimates using the SunScan mathematical model.

Wiring connections

The Beam Fraction sensor logging cable plugs into the BFS cable connector, giving up to 12 metres distance from the logger. If you need more length, simply join on extra screened multicore cable of a similar type. Make sure the joint is weatherproof.

The cores of the BFS logging cable have the following functionality:

Core

Function

Logger Connection

orange

V+

Power supply positive

Sensor power positive (switched for warm-up)

green

0V

Power supply negative

Sensor power negative (0V)

brown

HI

Total PAR signal output

Input channel +, for Total PAR

 

positive

 

grey

LO

Common signal output

Input channels - common negative

 

negative

 

blue

HI

Diffuse PAR signal output

Input channel +, for Diffuse PAR

 

positive

 

braid

Screen

Frame earth, or 0V

Note: the grey and green are connected internally in the BFS case. The braid is not connected to any other core.

Output

The output signals are the Total and the Diffuse PAR irradiance.

The millivolt outputs are linear, with a sensitivity of 1 mV = 1 mol.m-2.s-1. Maximum output is dependent on the supply voltage, and can exceed 2500 mV.

Logger requirements

The BFS requires a voltage supply of 5-15 V dc (unregulated), at about 1 mA current.

Warning! Pre-Release Beam Fraction sensors require a regulated voltage supply of

5V dc (± 0.25 V). Refer to Delta-T if you are uncertain about this.

Configure two logger channels for voltage input, with the above sensitivity.

Use a "warm-up" time of 1 second (the logger must apply the power 1 second before taking its reading). Outputs will be stable after 10 ms.

SunScan User Manual v 1.05

Appendices 75

Page 75
Image 75
Delta Electronics SS1-UM-1.05 user manual Logging the Beam Fraction sensor

SS1-UM-1.05 specifications

Delta Electronics has long been recognized for its innovative solutions in power and thermal management technologies. One of its notable products is the SS1-UM-1.05, a compact and efficient power supply module designed to meet the needs of a variety of applications, from industrial automation to telecommunications.

The Delta SS1-UM-1.05 is a key component in the company’s extensive portfolio, providing reliable and stable power supply for both demanding and sensitive electronic equipment. One of the main features of this module is its high efficiency, which typically exceeds 90%. This not only minimizes energy consumption but also reduces heat generation, making it an ideal choice for applications where thermal management is crucial.

Another significant characteristic of the SS1-UM-1.05 is its wide input voltage range, which allows it to operate effectively in various environments. The module supports a voltage range from 90 to 264 VAC, ensuring consistent performance even in fluctuating supply conditions. This versatility makes it well-suited for global applications, accommodating different electrical standards and requirements.

The SS1-UM-1.05 also boasts a compact footprint, which is essential for space-constrained installations. Its design emphasizes not only performance but also ease of integration into existing systems. The module provides multiple output voltage options, allowing it to cater to specific power requirements, whether it be for industrial machinery or consumer electronics.

In terms of technologies, the SS1-UM-1.05 incorporates advanced power conversion technologies that enhance its overall performance. It features overload protection and thermal shutdown mechanisms to safeguard both the module and the equipment it powers from potential damages due to electrical faults. Moreover, it has low electromagnetic interference (EMI) emissions, which is crucial for environments sensitive to electrical noise.

The SS1-UM-1.05 is also designed with a robust enclosure that adheres to stringent safety and environmental standards. This enhances its durability and reliability, ensuring it can withstand harsh operating conditions. With these features, Delta Electronics demonstrates its commitment to delivering high-quality products that meet the evolving needs of industries worldwide.

Overall, the Delta SS1-UM-1.05 power supply module is an exemplary solution for those seeking a reliable, efficient, and compact power source. Its advanced features and technologies make it an indispensable component in modern electronic systems.