Settings

Titles

Title

40 chars.

Title name is stored in the data file heading, and is displayed on

 

 

 

 

 

the Title screen.

 

 

(contd.)

 

Group

40 chars.

Name for a group of readings. A new name (or setting change)

 

 

 

 

 

starts a new group.

 

 

 

Site

Site Name

40 chars.

Name of your measurement site.

 

 

 

 

Latitude

-90°to +90°

Latitude of your measurement site. Use negative numbers south

 

 

 

 

 

of equator.

 

 

 

 

 

Longitude

-180°to

Longitude of your measurement site. Use negative numbers east

 

 

 

 

°

of Greenwich meridian.

 

 

 

 

 

+180

 

 

 

 

 

 

Time &

Local time

 

 

Set clock to the time at the measurement site.

 

Date

 

 

 

 

 

 

 

 

 

 

Date

 

 

Today’s date.

 

 

 

 

Local time

-12.0 to +13.0

Offset of local time zone from GMT. Remember to include

 

 

is GMT

 

 

provision for any local “Summer” time etc.

 

 

 

Display

Display:

LAI

Display:

Incident PAR

Solar Zenith

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmitted PAR

Photodiode spread

 

 

 

 

 

 

 

 

Beam Fraction

Leaf Area Index

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAR

Display:

 

 

 

 

 

 

 

 

Transmitted PAR

Photodiode spread

 

 

 

 

 

 

 

 

Incident total PAR

 

 

 

 

 

 

 

 

 

Incident diffuse PAR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All

Same as for PAR, but individual readings stored to the data file.

 

 

'Sample'

6 chars.

Change name if ‘Sample’ is not appropriate.

 

 

name

 

 

 

 

 

 

 

 

 

'Plot' name

6 chars.

Change name if ‘Plot’ is not appropriate.

 

 

 

 

 

 

 

 

 

 

 

Utils

Calibrate

Restore

 

 

Restores each photodiode's calibration coefficient as determined

 

 

Factory

 

 

by Delta-T.

 

 

 

 

 

Calibration

 

 

 

 

 

 

 

 

 

Recalibrate

 

 

Calculate and reset the individual photodiode calibration

 

 

SunScan

 

 

coefficients using the Beam Fraction sensor as a reference.

Autolog (setup screen)

 

 

SunScan will operate unattended in whatever mode has been set-

 

 

up. Complete all the screen entries then press Enter to initiate

 

 

Autolog process.

Start

Date, time

Type in start date and time. These can be in the past 24 hours to

 

 

allow alignment with particular periods.

Stop

Date, time

Type in date and time to finish. Must be in the future.

Read

hh:mm:ss

Type in the sampling interval. Every reading is stored.

interval

 

Minimum 00:00:01, maximum 23:59:59.

Average

hh:mm:ss

Stores averages at the specified interval. Should be a multiple of

interval

 

the read interval. Zero gives no averages.

Ignore

yes, no

Yes: readings are not taken at night.

nighttime?

 

No: readings are continuous.

(progress

Sleep, (or

Blanks the screen. This is the usual condition. Press On/Esc to re-

screen)

Off)

awaken it.

 

Cancel

Stops the Autolog process on demand.

Comms

 

Dumb terminal mode. Factory setup use only.

Test

 

 

About

 

Displays Psion SunData s/w version, and the battery voltage and

 

 

status for both the SunScan probe and Workabout.

SunScan User Manual v 1.05

Menus and Screens 31

Page 31
Image 31
Delta Electronics SS1-UM-1.05 user manual Contd, Utils

SS1-UM-1.05 specifications

Delta Electronics has long been recognized for its innovative solutions in power and thermal management technologies. One of its notable products is the SS1-UM-1.05, a compact and efficient power supply module designed to meet the needs of a variety of applications, from industrial automation to telecommunications.

The Delta SS1-UM-1.05 is a key component in the company’s extensive portfolio, providing reliable and stable power supply for both demanding and sensitive electronic equipment. One of the main features of this module is its high efficiency, which typically exceeds 90%. This not only minimizes energy consumption but also reduces heat generation, making it an ideal choice for applications where thermal management is crucial.

Another significant characteristic of the SS1-UM-1.05 is its wide input voltage range, which allows it to operate effectively in various environments. The module supports a voltage range from 90 to 264 VAC, ensuring consistent performance even in fluctuating supply conditions. This versatility makes it well-suited for global applications, accommodating different electrical standards and requirements.

The SS1-UM-1.05 also boasts a compact footprint, which is essential for space-constrained installations. Its design emphasizes not only performance but also ease of integration into existing systems. The module provides multiple output voltage options, allowing it to cater to specific power requirements, whether it be for industrial machinery or consumer electronics.

In terms of technologies, the SS1-UM-1.05 incorporates advanced power conversion technologies that enhance its overall performance. It features overload protection and thermal shutdown mechanisms to safeguard both the module and the equipment it powers from potential damages due to electrical faults. Moreover, it has low electromagnetic interference (EMI) emissions, which is crucial for environments sensitive to electrical noise.

The SS1-UM-1.05 is also designed with a robust enclosure that adheres to stringent safety and environmental standards. This enhances its durability and reliability, ensuring it can withstand harsh operating conditions. With these features, Delta Electronics demonstrates its commitment to delivering high-quality products that meet the evolving needs of industries worldwide.

Overall, the Delta SS1-UM-1.05 power supply module is an exemplary solution for those seeking a reliable, efficient, and compact power source. Its advanced features and technologies make it an indispensable component in modern electronic systems.