Displaying data files on your PC

As soon as you have transferred data files from the Workabout to your PC (or have created them on a portable PC) you will want to analyse and print them for your records.

The .PRN file

The .PRN file format contains ASCII characters which can be read by a wide range of text reading programs, and by some spreadsheets. An example printout is shown below.

Created by SunData for Workabout v0.11

Title

:Demonstration

Location

:Burwell,

Cambridge

Latitude

:52.2N

Longitude :0.4W

1996-05-19

 

Local time

is GMT+1 Hrs

 

 

 

 

SunScan probe

emulator

 

 

 

 

 

 

 

Ext sensor:BFS

Leaf Angle

Distn Parameter: 1.5

Leaf Absorption : 0.85

Group

1 :Presentation

 

 

 

 

 

 

 

Time

 

Plot

Sample Trans-

Spread

Incid-

Beam

Zenith

LAI Notes

 

 

 

 

mitted

 

ent

frac

Angle

 

 

15:51:12

 

1

1

270.9

0.13

2000.0

0.65

46.5

2.7

Notes appear here.

15:51:59

 

1

2

189.6

0.14

2000.0

0.65

46.6

3.2

 

15:52:08

 

1

3

1047.5

0.15

2000.0

0.65

46.6

0.8

 

15:52:16

 

1

4

63.4

0.14

2000.0

0.65

46.6

4.7

 

15:52:24

 

1

5

1225.3

0.15

2000.0

0.65

46.6

0.6

 

Average of

5

readings:

 

 

 

 

 

 

 

Incident light: 2000.0

Transmitted fraction:0.28

LAI:

2.4

 

The .CSV file

The Comma Separated Value format is a common format where ASCII characters are separated into fields by commas, and text is identified by being enclosed in "...". This greatly simplifies importing the files into spreadsheets for further analysis and printout. The example below was created in Microsoft Excel 5.0

Created by SunData for Workabout v0.11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Title

:

Demonstration2

 

 

 

 

 

 

 

 

 

 

 

Location :

Burwell, Cambridge

 

 

 

 

 

 

 

 

 

 

 

Latitude :

52.0N

Longitude :

0.1W

 

 

 

 

 

 

 

 

 

 

19/05/96

 

Local time is GMT+1 Hrs

 

 

 

 

 

 

 

 

 

SunScan probe emulator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ext sensor: None

Leaf Angle Distn Parameter:

 

 

2.5

Leaf Absorption :

 

0.9

 

 

Group

1 :

Presentation2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

 

Plot

Sample

Trans-

Spread

Incid-

Beam

 

Zenith

LAI

 

Notes

 

 

 

 

 

 

mitted

 

ent

frac

 

Angle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15:56:54

 

 

 

 

1662.4

 

0.37

 

 

 

Beam Fraction measm't

15:57:54

1

1

754.2

0.15

 

 

 

47.5

 

0.9

 

 

 

15:58:00

1

2

142.9

0.15

 

 

 

47.5

 

2.9

 

 

 

15:58:05

1

3

203.4

0.15

 

 

 

47.5

 

2.5

 

 

 

15:58:09

1

4

255.4

0.17

 

 

 

47.5

 

2.2

 

 

 

15:58:15

1

5

701.4

0.13

 

 

 

47.5

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Average of

5

readings:

 

 

 

 

 

 

 

 

 

 

 

Incident light:

1662.4

Transmitted fraction

 

 

0.25

LAI

 

1.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38 More Psion and file handling notes

Document code: SS1-UM-1.05

Page 38
Image 38
Delta Electronics SS1-UM-1.05 user manual Displaying data files on your PC, PRN file, CSV file

SS1-UM-1.05 specifications

Delta Electronics has long been recognized for its innovative solutions in power and thermal management technologies. One of its notable products is the SS1-UM-1.05, a compact and efficient power supply module designed to meet the needs of a variety of applications, from industrial automation to telecommunications.

The Delta SS1-UM-1.05 is a key component in the company’s extensive portfolio, providing reliable and stable power supply for both demanding and sensitive electronic equipment. One of the main features of this module is its high efficiency, which typically exceeds 90%. This not only minimizes energy consumption but also reduces heat generation, making it an ideal choice for applications where thermal management is crucial.

Another significant characteristic of the SS1-UM-1.05 is its wide input voltage range, which allows it to operate effectively in various environments. The module supports a voltage range from 90 to 264 VAC, ensuring consistent performance even in fluctuating supply conditions. This versatility makes it well-suited for global applications, accommodating different electrical standards and requirements.

The SS1-UM-1.05 also boasts a compact footprint, which is essential for space-constrained installations. Its design emphasizes not only performance but also ease of integration into existing systems. The module provides multiple output voltage options, allowing it to cater to specific power requirements, whether it be for industrial machinery or consumer electronics.

In terms of technologies, the SS1-UM-1.05 incorporates advanced power conversion technologies that enhance its overall performance. It features overload protection and thermal shutdown mechanisms to safeguard both the module and the equipment it powers from potential damages due to electrical faults. Moreover, it has low electromagnetic interference (EMI) emissions, which is crucial for environments sensitive to electrical noise.

The SS1-UM-1.05 is also designed with a robust enclosure that adheres to stringent safety and environmental standards. This enhances its durability and reliability, ensuring it can withstand harsh operating conditions. With these features, Delta Electronics demonstrates its commitment to delivering high-quality products that meet the evolving needs of industries worldwide.

Overall, the Delta SS1-UM-1.05 power supply module is an exemplary solution for those seeking a reliable, efficient, and compact power source. Its advanced features and technologies make it an indispensable component in modern electronic systems.