Equation fitting and inversion

The results of the computer modelling, while accurate, are not suitable for use in a field instrument. It takes many minutes of processing on a fast PC to calculate light transmission for any given conditions using the model, and the Psion Workabout is not a fast computer!. The model calculates values of light transmission for a given LAI, whereas the SunScan measures light transmission. This means that the functions have to be inverted to work back to LAI, which is more difficult.

To give you immediate results in the field, computable functions have been fitted to the model data, and it is these that are solved to give LAI to reasonable accuracy from the parameters measured by the SunScan system.

Note! Wood’s SunScan equations are copyright, and you should not copy them without written permission unless for purposes of scientific debate or publication, in which case they should be fully acknowledged.

Theory versus reality

We believe that Wood’s SunScan equations accurately reflect the assumptions that the modelling is based on.

By far the largest uncertainties are bound to be caused by

the mismatch between the real canopy architecture and the simplifying assumptions built into the fundamental analysis

to a lesser extent the uncertainty in the numerical values of ELADP estimated for your canopy.

With these caveats, the values of LAI for your canopy, even if of uncertain accuracy, will provide valid trends for a given canopy (e.g. canopy growth in a season), and valid comparisons between different canopies of similar architecture (e.g. trial plots of different cultivars of the same species). If you are able to compare SunScan estimates with actual harvested samples from time to time, this will enable you to calibrate out any systematic errors due to your canopy not matching the SunScan assumptions.

If you wish, you can force the SunScan calculations to be equivalent to older, less sophisticated inversions by setting some of the parameters to appropriate values. For example, setting ELADP to 1024 (horizontal leaves) and Absorption to 1.0 will give you the simple Beer’s law inversion.

Derivation of Wood’s SunScan canopy analysis equations

The major assumptions

The canopy is an infinite, uniform, horizontal slab, with leaf elements randomly distributed in proportion to the surface area of an ellipsoid, as described by Campbell.

The incident light consists of a component from a point source at a given zenith angle (the Direct beam); and a Diffuse component of equal intensity from every point in the sky (Uniform Overcast Sky).

The canopy either has sufficiently high LAI that light reflected back from the ground below is negligible, or the reflectance of the ground is similar to that of the canopy.

Of the light intercepted by the leaf element, a fraction a (absorption) is totally absorbed. The remainder is re-emitted uniformly in all directions.

SunScan User Manual v 1.05

LAI theory 55

Page 55
Image 55
Delta Electronics SS1-UM-1.05 user manual Derivation of Wood’s SunScan canopy analysis equations, Major assumptions

SS1-UM-1.05 specifications

Delta Electronics has long been recognized for its innovative solutions in power and thermal management technologies. One of its notable products is the SS1-UM-1.05, a compact and efficient power supply module designed to meet the needs of a variety of applications, from industrial automation to telecommunications.

The Delta SS1-UM-1.05 is a key component in the company’s extensive portfolio, providing reliable and stable power supply for both demanding and sensitive electronic equipment. One of the main features of this module is its high efficiency, which typically exceeds 90%. This not only minimizes energy consumption but also reduces heat generation, making it an ideal choice for applications where thermal management is crucial.

Another significant characteristic of the SS1-UM-1.05 is its wide input voltage range, which allows it to operate effectively in various environments. The module supports a voltage range from 90 to 264 VAC, ensuring consistent performance even in fluctuating supply conditions. This versatility makes it well-suited for global applications, accommodating different electrical standards and requirements.

The SS1-UM-1.05 also boasts a compact footprint, which is essential for space-constrained installations. Its design emphasizes not only performance but also ease of integration into existing systems. The module provides multiple output voltage options, allowing it to cater to specific power requirements, whether it be for industrial machinery or consumer electronics.

In terms of technologies, the SS1-UM-1.05 incorporates advanced power conversion technologies that enhance its overall performance. It features overload protection and thermal shutdown mechanisms to safeguard both the module and the equipment it powers from potential damages due to electrical faults. Moreover, it has low electromagnetic interference (EMI) emissions, which is crucial for environments sensitive to electrical noise.

The SS1-UM-1.05 is also designed with a robust enclosure that adheres to stringent safety and environmental standards. This enhances its durability and reliability, ensuring it can withstand harsh operating conditions. With these features, Delta Electronics demonstrates its commitment to delivering high-quality products that meet the evolving needs of industries worldwide.

Overall, the Delta SS1-UM-1.05 power supply module is an exemplary solution for those seeking a reliable, efficient, and compact power source. Its advanced features and technologies make it an indispensable component in modern electronic systems.