| Parameter | Explanation | Settings | Factory | Customer |
|
| Setting |
| ||||
| Pr.59 | Electronic Thermal | 30 to 300 sec | 60 |
|
|
| Motor Overload |
|
| |||
|
|
|
|
|
| |
|
|
| 00: |
|
|
|
|
|
| 01: Enabled during constant speed |
|
|
|
|
|
| operation until the allowable time for |
|
|
|
|
|
| detection (Pr.62) elapses. |
|
|
|
|
| 02: Enabled during constant speed |
|
|
| |
| Pr.60 | operation and halted after detection. | 00 |
|
| |
| Mode |
|
| |||
|
| 03: Enabled during acceleration until the |
|
|
| |
|
|
|
|
|
| |
|
|
| allowable time for detection (Pr.62) |
|
|
|
|
|
| elapses. |
|
|
|
|
|
| 04: Enabled during acceleration and |
|
|
|
|
|
| halted after detection. |
|
|
|
| Pr.61 | 30 to 200 % | 150 |
|
| |
| Level |
|
| |||
|
|
|
|
|
| |
| Pr.62 | 0.0 to 10.0 seconds | 0.1 |
|
| |
| Time |
|
| |||
|
|
|
|
|
| |
|
|
| 00: Decelerate to 0 Hz |
|
|
|
| Pr.63 | Loss of ACI | 01: Stop immediately and display "EF" | 00 |
|
|
| 02: Continue operation by last frequency |
|
| |||
|
|
|
|
|
| |
|
|
| command |
|
|
|
|
|
| 00: Display AC drive output Frequency |
|
|
|
|
|
| (Hz) |
|
|
|
|
|
| 01: Display |
|
|
|
|
|
| Frequency (H*Pr.65) |
|
|
|
|
|
| 02: Output Voltage (E) |
|
|
|
|
|
| 03: DC Bus Voltage (u_) |
|
|
|
|
|
| 04: PV (i) |
|
|
|
| Pr.64 | User Defined Function | 05: Display the value of internal counter | 06 |
|
|
| for Display | (c) |
|
| ||
|
|
|
|
| ||
|
|
| 06: Display the setting frequency (F or |
|
|
|
|
|
| o=%) |
|
|
|
|
|
| 07: Display the parameter setting (Pr.00) |
|
|
|
|
|
| 08: Reserved |
|
|
|
|
|
| 09: Output Current (A) |
|
|
|
|
|
| 10: Display program operation (0.xxx), |
|
|
|
|
|
| Fwd, or Rev |
|
|
|
| Pr.65 | Coefficient K | 0.01 to 160.0 | 1.00 |
|
|
|
|
|
|
|
|
|
| Pr.66 | Communication | 0.00 to 400.0 Hz | 0.00 |
|
|
| Frequency |
|
| |||
|
|
|
|
|
| |
| Pr.67 | Skip Frequency 1 | 0.00 to 400.0 Hz | 0.00 |
|
|
|
|
|
|
|
|
|
| Pr.68 | Skip Frequency 2 | 0.00 to 400.0 Hz | 0.00 |
|
|
| Pr.69 | Skip Frequency 3 | 0.00 to 400.0 Hz | 0.00 |
|
|
|
|
|
|
|
|
|
| Pr.70 | Skip Frequency Band | 0.00 to 20.00 Hz | 0.00 |
|
|
|
| PWM Carrier | 01 to 15 | 15 |
|
|
| Pr.71 | The factory setting of VFD075M43A is 10. |
|
| ||
| Frequency |
|
|
| ||
|
| 575V series: 01 to 10 | 6 |
|
| |
|
|
|
|
| ||
| Pr.72 | Auto Restart Attempts | 00 to 10 | 00 |
|
|
| after Fault |
|
| |||
|
|
|
|
|
|