09: Resets all parameters to 50Hz factory

 

Parameter

Explanation

Settings

Factory

Customer

 

 

Setting

 

 

Pr.73

Present Fault Record

00: No fault occurred

00

 

 

 

 

 

01: Over-current (oc)

 

 

 

 

 

 

 

 

 

 

Pr.74

Second Most Recent

02: Over-voltage (ov)

00

 

 

 

Fault Record

03: Overheat (oH)

 

 

 

 

 

 

 

 

 

 

04: Overload (oL)

 

 

 

 

 

 

 

 

 

 

 

 

05: Overload 1 (oL1)

 

 

 

 

 

 

06: External Fault (EF)

 

 

 

 

 

 

07: CPU failure 1 (CF1)

 

 

 

 

 

 

08: CPU failure 3 (CF3)

 

 

 

 

 

 

09: Hardware Protection Failure (HPF)

 

 

 

 

 

 

10: Over-current during acceleration (oca)

 

 

 

 

 

 

11: Over-current during deceleration

 

 

 

 

 

 

(ocd)

 

 

 

 

 

Third Most Recent

12: Over-current during steady state

 

 

 

 

Pr.75

operation (ocn)

00

 

 

 

Fault Record

 

 

 

 

13: Ground fault or fuse failure(GFF)

 

 

 

 

 

 

 

 

 

 

 

 

14: Low Voltage (not record)

 

 

 

 

 

 

15: 3 Phase Input Power Loss

 

 

 

 

 

 

16: EPROM failure (CF2)

 

 

 

 

 

 

17: External interrupt allowance(bb)

 

 

 

 

 

 

18: Overload (oL2)

 

 

 

 

 

 

19: Auto Adjustable accel/decel failure

 

 

 

 

 

 

(CFA)

 

 

 

 

 

 

20: CPU self detection failure (codE)

 

 

 

 

 

 

00: All parameters can be set/read

 

 

 

 

 

 

01: All parameters are read-only

 

 

 

 

Pr.76

Parameter Lock and

02-08: Reserved

 

 

 

 

09: Resets all parameters to 50Hz factory

00

 

 

 

Configuration

 

 

 

 

defaults

 

 

 

 

 

 

 

 

 

 

 

 

10: Resets all parameters to 60Hz factory

 

 

 

 

 

 

defaults

 

 

 

 

 

Time for Auto Reset the

 

 

 

 

 

Pr.77

Restart Times in

0.1 to 6000.0 sec

60.0

 

 

 

 

Abnormality

 

 

 

 

 

 

 

00: Disable PLC operation

 

 

 

 

 

 

01: Execute one program cycle

 

 

 

 

 

 

02: Continuously execute program cycles

 

 

 

 

Pr.78

PLC Operation Mode

03: Execute one program cycle step by

00

 

 

 

 

 

step

 

 

 

 

 

 

04: Continuously execute one program

 

 

 

 

 

 

cycle step by step

 

 

 

 

Pr.79

PLC FWD/REV Motion

00 to 127

00

 

 

 

Pr.80

Identity Code of the AC

Read only

##

 

 

 

 

Motor Drive

 

 

 

 

 

Pr.81

Time Duration of 1st

00 to 9999 sec

00

 

 

 

Step Speed

 

 

 

 

 

 

 

 

 

Pr.82

Time Duration of 2nd

00 to 9999 sec

00

 

 

 

Step Speed

 

 

 

 

 

 

 

 

 

Pr.83

Time Duration of 3rd

00 to 9999 sec

00

 

 

 

Step Speed

 

 

 

 

 

 

 

 