Parameter

Explanation

Settings

Factory

Customer

 

 

Setting

 

 

Pr.119

Differential Time (D)

0.00 to 1.00 sec

0.00

 

 

 

 

 

 

 

 

 

 

Pr.120

Integration’s Upper

00 to 100 %

100 %

 

 

 

Bound Frequency

 

 

 

 

 

 

 

 

 

Pr.121

One-Time Delay

0.0 to 2.5 sec

0.0

 

 

 

 

 

 

 

 

 

 

Pr.122

PID Frequency Output

00 to 110 %

100

 

 

 

Command Limit

 

 

 

 

 

 

 

 

 

Pr.123

Feedback Signal

0.0: Disable

60.0

 

 

 

Detection Time

0.1 to 3600 sec

 

 

 

 

 

 

 

 

Pr.124

Feedback Signal Fault

00: Warning and RAMP to stop

00

 

 

 

Treatment

01: Warning and keep operating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.125

Source of PID Set Point

0.00 to 400.0Hz

0.00

 

 

 

Pr.126

PID Offset Level

1.0 to 50.0 %

10.0

 

 

 

Pr.127

Detection Time of PID

0.1 to 300.0 sec

5.0

 

 

 

Offset

 

 

 

 

 

 

 

 

 

Pr.128

Minimum Reference

0.0 to 10.0 V

0.0

 

 

 

Value

 

 

 

 

 

 

 

 

 

Pr.129

Maximum Reference

0.0 to 10.0 V

10.0

 

 

 

Value

 

 

 

 

 

 

 

 

 

Pr.130

Invert Reference Signal

00: Not inverted

00

 

 

 

AVI (0-10V)

01: Inverted

 

 

 

 

 

 

 

 

Pr.131

Minimum Reference

0.0 to 20.0mA

4.0

 

 

 

Value (4-20mA)

 

 

 

 

 

 

 

 

 

Pr.132

Maximum Reference

0.0 to 20.0mA

20.0

 

 

 

Value (4-20mA)

 

 

 

 

 

 

 

 

 

Pr.133

Invert Reference Signal

00: Not inverted

00

 

 

 

(4-20mA)

01: Inverted

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.134

Analog Input Delay

00 to 9999 (per 2ms)

50

 

 

 

Filter for Set Point

 

 

 

 

 

 

 

 

 

 

Analog Input Delay

 

 

 

 

 

Pr.135

Filter for Feedback

00 to 9999 (per 2ms)

5

 

 

 

 

Signal

 

 

 

 

 

Pr.136

Sleep Period

0.0 to 6550.0 sec

0.0

 

 

 

Pr.137

Sleep Frequency

0.00 to 400.0 Hz

0.00

 

 

 

Pr.138

Wake Up Frequency

0.00 to 400.0 Hz

0.00

 

 

 

Pr.139

Treatment for Counter

00: Continue operation

00

 

 

 

Attained

01: Stop Immediately and display E.F.

 

 

 

 

 

 

 

 

Pr.140

External Up/Down

00: Fixed Mode (keypad)

 

 

 

 

01: By Accel or Decel Time

00

 

 

 

Selection

 

 

 

 

02: Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.141

Save Frequency Set

00: Not Save

01

 

 

 

Point

01: Save

 

 

 

 

 

 

 

English-17

Page 17
Image 17
Delta Electronics VFD-XXXM quick start English-17

VFD-XXXM specifications

Delta Electronics VFD-XXXM series represents a cutting-edge advancement in variable frequency drive (VFD) technology, catering to a diverse range of industrial applications. Designed for efficiency, reliability, and ease of integration, the VFD-XXXM series is an ideal choice for motor control systems in various sectors, including manufacturing, HVAC, and water treatment.

One of the standout features of the VFD-XXXM is its precise motor control capability. The drive supports multiple control modes, including V/f control, Vector Control, and Sensorless Vector Control, allowing users to optimize performance based on application needs. This flexibility ensures smooth operation and improved energy efficiency, making it suitable for both simple and complex motor tasks.

In terms of design, the VFD-XXXM series is compact and user-friendly. With an intuitive keypad and clear display, operators can easily navigate and configure the settings. This ease of use significantly reduces setup time and enhances operational efficiency. Additionally, the unit’s robust construction allows it to perform reliably in harsh industrial environments, with features such as IP20/IP55 protection ratings, making it resistant to dust and moisture.

One of the key technologies embedded in the VFD-XXXM is the Advanced Energy Saving Algorithm, which continuously optimizes the energy consumption of the connected motor. This feature not only reduces operational costs but also contributes to environmental sustainability initiatives by minimizing power waste.

The series boasts an extensive array of communication options, including Modbus, CANopen, and Ethernet interfaces, enabling seamless integration with existing automation systems. This connectivity enhances flexibility and allows for real-time monitoring and control, improving overall system performance.

Moreover, the VFD-XXXM includes comprehensive built-in safety features, such as overload protection, short circuit protection, and a safe torque off function. These safety characteristics ensure the protection of both the drive and the motor, promoting a secure operational environment.

In conclusion, Delta Electronics VFD-XXXM series stands out due to its advanced features, robust design, and energy-efficient technologies. Its versatility makes it an exceptional choice for varied industrial applications, providing businesses with reliable and sustainable motor control solutions that enhance both performance and efficiency.