19 TROUBLESHOOTING

ENGLISH

19 TROUBLESHOOTING

If a problem should arise,first check the following.

1.Are the connections correct ?

2.Have you operated the receiver according to the Operating Instructions ?

3.Are the speakers, turntable and other components operating property ?

If this unit is not operating properly, check the items listed in the table below. Should the problem persist, there may be a malfunction. Disconnect the power immediately and contact your store of purchase.

 

 

Symptom

 

 

Cause

 

 

Measures

 

Page

 

 

 

 

 

 

 

 

DISPLAY not lit and sound not produced

• Power cord not plugged in securely.

• Check the insertion of the power cord plug.

9

 

 

 

 

 

 

 

 

• Turn the power off with the remote control

25

 

 

when power switch set to on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unit after turning the POWER operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switch on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Speaker cords not securely connected.

• Connect securely.

 

 

14, 15

 

 

 

• Improper position of the audio function

• Set to a suitable position.

 

26

to the

etc.

 

button.

 

 

 

 

 

 

 

 

 

DISPLAY lit but sound not produced.

• Volume control set to minimum.

• Turn volume up to suitable level.

 

27

 

• MUTING is on.

 

 

 

• Switch off MUTING.

 

28

Common problems arising when listening

CD, records, tapes, and FM broadcasts,

 

 

 

 

 

 

• Digital signals not

input

Digital input

• Input digital signals or select input jacks to

27

 

selected.

 

 

 

 

 

which digital signals are being input.

 

 

 

 

 

 

 

 

• Speaker terminals are short-circuited.

• Switch power

off, connect

speakers

14, 15

 

 

 

 

 

 

 

properly, then switch power back on.

 

 

• Block the ventilation holes of the set.

• Turn off the set’s power, then ventilate it

5, 15

DISPLAY not displayed and the

 

 

 

 

 

 

well to cool it down.

 

 

 

 

 

 

 

 

Once the set is

cooled down,

turn the

 

“ON/STANDBY” LED flashes at a high

 

 

 

 

 

 

 

 

 

 

 

 

 

power back on.

 

 

 

rate

 

 

 

 

 

 

 

 

 

• The unit is operating at continuous high

• Turn off the set’s power, then ventilate it

5, 15

 

 

power

conditions

and/or

inadequate

well to cool it down.

 

 

 

ventilation.

 

 

 

 

Once the set is cooled down, turn the

 

 

 

 

 

 

 

 

power back on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Incomplete connection of speaker cords.

• Connect securely.

 

 

14, 15

 

 

 

 

 

 

 

Sound produced only from one channel.

• Incomplete

connection

of

input/output

• Connect securely.

 

 

9 ~ 14

 

 

 

cords.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Positions of instruments reversed during

• Reverse

connections

of left and right

• Check left and right connections.

 

14

 

 

speakers

or

left and right

input/output

 

 

 

 

 

 

stereo playback.

 

 

 

 

 

 

cords.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unit.

 

• Batteries dead.

 

 

 

• Replace with new batteries.

 

16

control

 

• Remote control unit too far from this unit.

• Move closer.

 

 

16

 

• Remove obstacle.

 

 

16

This unit does not operate properly when

• Obstacle

between this

unit

and remote

 

 

 

 

 

 

remote control unit is used.

control unit.

 

 

 

 

• Press the proper button.

 

Remote

 

 

 

 

 

 

• Different button is being pressed.

 

 

• Insert batteries properly.

 

16

 

<and >ends of battery inserted in reverse.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

When a subwoofer has been connected and the virtual surround function is being used, the signal played from the subwoofer channel is LFE only (only when playing Dolby Digital or DTS signals) for initial factory settings (i.e., the setting of the front speaker is “LARGE” and the setting of the subwoofer mode is “NORM”).

When subwoofer effects are felt to be weak, while in the system setup mode try setting the subwoofer mode to “+MAIN”, or the front speaker to “SMALL” in the Speaker Configuration settings.

Making these settings will result in the low-frequency sounds of the front channel being played from the subwoofer.