Desa BY70CEB Service Procedures, Portable Forced Air Heaters, Upper Shell Removal, Fuel Filter

Models: BY100CEB BY35CEB BY70CEB BY150CEB

1 24
Download 24 pages 9 Kb
Page 8
Image 8
SERVICE

R

PORTABLE FORCED AIR HEATERS

SERVICE

PROCEDURES

Upper Shell Removal WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur.

Upper Shell Removal

1.Remove screws and lock washers along each side of heater using 5/16" nut- driver. These screws attach upper and lower shells together.

2.Lift upper shell off.

3.Remove fan guard.

Fuel Filter

(35/70,000 Btu/Hr Models)

1.Remove side cover screws using 5/16" nut-driver.

2.Remove side cover.

3.Pull rubber fuel line off fuel filter neck.

4.Carefully pry bushing and fuel filter out of fuel tank.

5.Wash fuel filter with clean fuel and re- place in tank.

6.Attach rubber fuel line to fuel filter neck.

7.Replace side cover.

Fuel Filter

Upper Shell

Upper

 

Shell

 

Fan

 

Guard

Fuel Filter Fan

Guard

Figure 7 - Upper Shell Removal, 35/70,000

Figure 8 - Upper Shell Removal, 100/

Btu/Hr Models

150,000 Btu/Hr Models

Fuel Filter

 

Side Cover

Fuel Line

Figure 9 - Fuel Filter Removal, 35/70,000 Btu/Hr Models

(100/150,000 Btu/Hr Models)

1.Remove side cover screws using 5/16" nut-driver.

2.Remove side cover.

3.Pull upper fuel line off fuel filter neck.

4.Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank.

5.Wash fuel filter with clean fuel and re- place in tank.

6.Attach upper fuel line to fuel filter neck.

7.Replace side cover.

Fuel Filter, Bushing, and Lower Fuel Line

Upper Fuel Line

Side Cover

Figure 10 - Fuel Filter Removal, 100/150,000 Btu/Hr Models