Troubleshooting

Troubleshooting

Note: Before troubleshooting system, make sure power to circuit from breaker or fuse panel

is turned ON.

The three most common causes of a malfunctioning electric fireplace are:

1.Tripped circuit breaker or blown fuse.

2.Loose or burned out light bulb.

3.Obstructed or clogged fan blower.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

No operation or indicator light

1.

No power to fireplace

1.

Check circuit breaker or fuse

at power/heater switch

2.

Defective switch lamp

2.

Replace defective switch.

 

 

 

 

See Servicing Control Pan-

 

 

 

 

el, page 17

 

3.

Defective wiring

3.

Check connections from

 

 

 

 

main power harnesses to

 

 

 

 

terminals on control panel.

 

 

 

 

See Servicing Control Pan-

 

 

 

 

el, page 17

Poor flame motion; flame pat- tern is sporadic or uneven in viewing area

1.Tangled or loose flame pennants

2.Obstructed or clogged fan blower

3.Damaged or dislodged fan blower wheel

1.Inspect flame pennants. Un- tangle or replace if neces- sary. See Servicing Flame

Pennants, page 19

2.Check fan blower for de- bris. Vacuum areas around blower wheel and remove any obstructions. See Main- taining Motors, page 16

3.Remove and inspect fan blower housing See Servic- ing Fan Blower, page 19

Dull flame appearance or inac- 1.

Burned out or loose light

tive ember bed effect

bulb

2.

Broken lamp fixture

3.

Loose or missing reflective

 

ribbons

1.Inspect light bulbs; tighten or replace light bulbs as necessary. See Replacing

Light Bulbs, page 16

2.Remove and replace broken lamp fixture. See Replacing Lamp Fixtures, page 20

3.Inspect reflective ribbons. Reattach or replace as nec- essary. See Replacing Re- flective Ribbons, page 20

No heat or intermittent heat 1. Obstructed heater blower

1. Clear heater fan of debris

output. (If equipped with a

or blockage; vacuum area

heater)

around blower intake and

 

remove any obstructions

 

in the discharge area. See

 

Maintaining Motors, page 16

2. Burned out heat element

2. Remove and replace blower

or blower fan

heater assembly. To access

 

and remove see Optional

 

Heater Accessory, page

 

10

3. Defective heater switch or

3. Inspect wiring connections

wiring

from switch to blower. Re-

 

place switch if defective.

 

See Servicing Control Pan-

 

el, page 17

14