MAINTENANCE
Continued
Base
Cover
Figure 34 - Removing Base Cover
Servicing Fan Blower
To remove fan blower:
1.Follow instructions under Accessing Imag- ing Unit, page 18.
2.Remove 3 light bulbs from lamp fixtures (see Replacing Light Bulbs, page 16).
3.Disconnect two 1/4" blade connectors at from posts on motor unit.
4.Remove 4 hex nuts and washers located on blower mounts at base of cabinet (see Figure 35).
5.Lift entire fan assembly off of mounts and tilt out of unit.
6.Remove screws with washers and hex nuts from fan housing.
7.Mount new fan to blower mount in reverse order.
8.Slide blower assembly with spacers over mounting lugs and replace washer and nut at each lug. Do not over tighten.
9.Attach blade connectors to posts on motor mount.
Note: Wire connectors for fan motor are
Servicing Flame Pennants
If flame pennants should become tangled or detached reattach or replace.
1.Locate affected flame pennant. Slip hem at base of flame pennant over proper hanger bracket position. See Figure 36, page 20, for proper location.
2.Pull flame cord up to proper hook location, use a slip knot to adjust cord length and attach cord to hook.
3.Tie another knot over slip knot and trim away excess cord.
Hex Nut | Washer Hex | |
Washer | Nut Blower | |
Spacer | Mount | |
(1 of 4) | ||
|
Screw
Fan Assembly
Posts for Blade
Connectors
Figure 35 - Removing Fan Assembly (Shown without Firebox for Clarity)
www.desatech.com | 19 |