Desa E36LH, E36LBH, E32L Maintenance, Continued, Servicing Fan Blower, Servicing Flame Pennants

Models: E32LB E36L E36LH E32L E32LH E36LB E36LBH E32LBH

1 28
Download 28 pages 45.27 Kb
Page 19
Image 19
Figure 34 - Removing Base Cover

MAINTENANCE

Continued

Base

Cover

Figure 34 - Removing Base Cover

Servicing Fan Blower

To remove fan blower:

1.Follow instructions under Accessing Imag- ing Unit, page 18.

2.Remove 3 light bulbs from lamp fixtures (see Replacing Light Bulbs, page 16).

3.Disconnect two 1/4" blade connectors at from posts on motor unit.

4.Remove 4 hex nuts and washers located on blower mounts at base of cabinet (see Figure 35).

5.Lift entire fan assembly off of mounts and tilt out of unit.

6.Remove screws with washers and hex nuts from fan housing.

7.Mount new fan to blower mount in reverse order.

8.Slide blower assembly with spacers over mounting lugs and replace washer and nut at each lug. Do not over tighten.

9.Attach blade connectors to posts on motor mount.

Note: Wire connectors for fan motor are non-polarized and may be connected to either terminal for proper operation.

Servicing Flame Pennants

If flame pennants should become tangled or detached reattach or replace.

1.Locate affected flame pennant. Slip hem at base of flame pennant over proper hanger bracket position. See Figure 36, page 20, for proper location.

2.Pull flame cord up to proper hook location, use a slip knot to adjust cord length and attach cord to hook.

3.Tie another knot over slip knot and trim away excess cord.

Hex Nut

Washer Hex

Washer

Nut Blower

Spacer

Mount

(1 of 4)

 

Screw

Fan Assembly

Posts for Blade

Connectors

Figure 35 - Removing Fan Assembly (Shown without Firebox for Clarity)

111076-01F

www.desatech.com

19

Page 19
Image 19
Desa E36LH, E36LBH, E32LH Maintenance, Continued, Servicing Fan Blower, Servicing Flame Pennants, Removing Base Cover