Cleaning Viewing Screen

MAINTENANCE

Continued

3.If upper back cabinet ribbons need re- placing, remove 4 Phillips screws holding corresponding bottom and top hanger brackets (see Figure 37, page 21).

4.Remove any loose or damaged ribbon material.

5.Cut an 18” strip of reflective ribbon and position top end about an inch above top bracket position (see Figure 37, page 21).

Note: Ribbon material should be ap- plied with reflective side up, should not be twisted or tangled, and should hang slightly loose to allow free movement. If additional parts are required, see Re- placement Parts, page 23.

6.Replace top hanger bracket using 2 Phil- lips screws removed in step 2 and tighten until reflective ribbon is held in place.

7.Replace bottom hanger bracket using 2 remaining Phillips screws to secure lower end of reflective ribbon.

8.If replacing reflective ribbons located in base, remove screws and washers at damaged ends of ribbon.

9.Cut a 9" long strip of ribbon and apply across each ribbon support bracket with shiny side facing up (see Figure 37, page 21).

10.Secure ribbon to brackets by replacing each washer at end of the ribbon and re- threading screws through the ribbon into each hole located on support brackets.

11.If replacing top reflective ribbons on base cover, cut a 3" section of ribbon and split down the middle. With shiny side up, attach with cellophane tape into rear edge of base cover opening (see Figure 37, page 21).

12.Readjust flame pennants (if removed). See Servicing Flame Pennants, page 19.

13.Reassemble imager. See Accessing Imaging Unit, page 18.

14.Center log bed over opening between viewing panel screen and grate.

15.Cover remaining hearth area with 1/4" of lava rock (provided), if desired.

Cleaning Viewing Screen

Clean viewing screen with an alcohol based, nonabrasive, residue free cleaner (premoist- ened hand wipes are ideal). Do not use glass cleaners with ammonium, abrasive scrubs or degreaser solvents of any kind.

Accessing Imaging Unit For Replacement

The imaging unit can be removed from inside the firebox for servicing or replacement:

1.Follow steps under Accessing Imaging Unit, on page 18.

2.Remove 4 hex screws on lower louver panel and detach louver assembly from front face (see Figure 38).

3.Rotate top edge of lower frame rail inward and lift upward until locking tabs detach from front face (see Figure 38).

4.Slide entire imaging unit forward and lift out through front opening (see Figure 39, page 23).

Note: An additional 3 feet of harness is tucked behind imager to permit removal without dis- connecting any control wiring.

Lower

Frame

Rail

Lower Panel

Lower Frame Accessing Imaging Unit For ReplacementFigure 38 - Removing Lower Louver

Rail

Locking Tab

Figure 38 - Removing Lower Louver
Panel and Frame Rail