PRESSURE TESTING FIREPLACE GAS CONNECTIONS

INSTALLATION

Continued

PRESSURE TESTING FIREPLACE GAS CONNECTIONS

1.Open equipment shutoff valve (see Figure 27, page 19).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Place manual ignition switch in the OFF position.

4.Check all joints from equipment shutoff valve to gas valve (see Figure 28 or 29). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fireplace, page 25). Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 27).

Equipment Shutoff Valve

Gas Meter

Manual Gas Valve

Figure 28 - Checking Gas Joints for

Natural Gas Fireplace

Equipment Shutoff Valve

Propane/LP

Supply Tank

Manual Gas Valve

Figure 29 - Checking Gas Joints for
Propane/LP Gas Fireplace

CONVENTIONAL FIREPLACE INSTALLATION

Conventional installation of fireplace involves in- stalling fireplace along with corner, face or cabinet mantel with hearth base accessories against a wall in your home. Follow instructions below to install fireplace in this manner.

Note: The instructions below show installation us- ing the cabinet mantel and hearth base accessories (see Accessories, page 40). The hearth base acces- sory shown is optional for this installation. You can install fireplace and cabinet mantel directly on the floor. The corner mantel accessory cannot be installed with the hearth bases. You must install corner mantel directly on the floor.

1.Assemble cabinet mantel, hearth base and trim accessories. Assembly instructions are included with each accessory.

2.When installing blower, install a properly grounded, 120 volt three-prong electrical out- let at fireplace location if an outlet is not there. If possible, locate outlet so cabinet mantel will cover it when installed (see Figure 30).

3.If not already completed, install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, page 17.

4.Place hearth base accessory against wall at installation location. Cut an access hole in hearth top to run flexible gas line to fireplace (see Figure 30). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over.

 

 

Electrical

Gas

 

Rigid Pipe

Outlet

 

 

Line

 

and Gas

 

Hearth

 

Access

Shutoff Valve

Hole

Base

 

 

 

 

 

Figure 30 - Placing Hearth Base Accessory Against Wall

20