OPERATING FIREPLACE
Continued
NORMAL LIGHTING
INSTRUCTIONS
WARNING: You must oper- ate this heater with the fireplace screen in place. Make sure fire- place screen is in place before running heater.
NOTICE:Duringinitialoperationof new heater, burning logs will give off a
1.STOP! Read the safety information on page 25.
2.Make sure equipment shutoff valve is fully open.
3.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Follow “B” on page 25. If you donʼt smell gas, go to the next step.
A. Using Supplied Wall Switch Assembly
1.Set manual ignition bypass switch on the control panel to the OFF position (auto- matic ignition position).
2.Press ON/OFF button. Hold for 6 seconds. Gas valve will open and electronic ignition will begin sparking to light pilot. LED will light. Note: You may be running this heater for the first time after connecting to gas sup- ply or at the start of your heating season. If so, the ON/OFF button may need to be pressed again. This will allow air to bleed from gas system. If several attempts to light pilot fail, contact a qualified service person or gas supplier for repairs. Until repairs are made, light and operate manually (see Manual Lighting Instructions for Electric Power Outage, page 27).
3.When pilot flame is lit, the thermocouple is heated by the flame. When thermocouple becomes hot (5 to 15 seconds), main burner will automatically light on high flame.
4.To lower flame, push HI/LO button on wall switch once. Note: This fireplace does not have a
CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.
| Manual Ignition Bypass Switch | |
HI/LO | (Up is for Remote Control) | |
|
| |
Button |
|
|
|
| ON/OFF |
|
| Button |
|
| Wall |
|
| Switch |
| LED | Assembly |
|
| |
Figure 47 - Control Locations |
Pilot | Manual Ignitor | Automatic | |
Electrode | |||
Burner | |||
| Ignitor | ||
|
| ||
|
| Electrode |
Figure 48 - Pilot (Natural Gas)
| Manual Ignitor |
|
Pilot | Electrode | Automatic |
Burner |
| Ignitor |
|
| Electrode |
Figure 49 - Pilot (Propane/LP Gas) | ||
B. Using | ||
Control |
|
|
1.Set manual ignition bypass switch on control panel to OFF position (automatic ignition position).
2.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Follow “B” on page 25, column 2. If you donʼt smell gas, go to the next step.
3.Point remote control toward the lower front of fireplace and push both buttons at the same time. Hold for 6 seconds. The gas valve will open and electronic igni- tion will begin sparking to light the pilot. Note: You will be able to hear a clicking sound during this process. LED on wall
switch will light.
26 | www.desatech.com |