Figure 6 - Removing Fireplace Floor

INSTALLATION

Continued

3.Remove screws that attach fireplace floor as- sembly to fireplace. Open lower louver door. Carefully lift up fireplace floor assembly and remove from fireplace, taking care to pull flexible gas line through the access holes (see Figure 6). Note: Be careful of all wires on underside of log base.

ELECTRICAL CONNECTIONS FOR POWER CORD CAUTION: Do not pick up fireplacefloorassemblybyburn- ers. This could damage burners. Only handle base by grates.

Flexible Gas Line

Screws

Fireplace Floor

Assembly

Figure 6 - Removing Fireplace Floor

Assembly

ELECTRICAL CONNECTIONS FOR POWER CORD

This fireplace operates on 120 VAC, 60 Hz power. An electrical power cord is supplied with this unit.

For Mantel Installation

1.Determine from which side of the fireplace the power cord will exit. Locate the 1.5" diameter hole near the center of floor support bracket on appropriate side of lower cavity (see Figure 7).

2.Locate power cord. Remove wire tie or tape holding plug end of power cord.

3.Power cord has 2 plastic hole bushings threaded onto it. Route cordʼs 3-prong plug through the 1.5" diameter hole in appropriate floor support bracket.

4.Push first plastic bushing completely through hole. Squeeze bushing as needed to do this.

5.Install the second plastic bushing into the hole in the floor support bracket by snapping into place.

6.Route the 3-prong plug through the 1.5" hole in fireplace outer casing.

7.Install the first plastic bushing into this hole by snapping into place.

8.After you have connected to gas supply and checked your gas connections (see pages 17 through 20), plug power cord into any conve- nient 3-prong grounded wall receptacle near fireplace.

For Recessed Installation

 

If an outlet is not installed in fireplace, install

model GA3555 - Outlet Kit with Cover. This

kit will supply a convenient 3-prong grounded

electrical outlet for power. Refer to installation

manual provided with this optional accessory for

instructions on wiring. Note: A qualified installer

must make all electrical connections.

Hole in Floor

Hole in Outer

Support Bracket

Casing

Bushings

For Mantel Installation Power

Cord

Figure 7 - Routing Power Cord

RELOCATING WALL SWITCH ASSEMBLY

Note: The decorative wall switch plate supplied is white. The wall switch plate may be painted to match your decor.

The push-button switch and decorative wall plate assembly supplied with your fireplace is pre-mounted at the factory in the lower cavity of the fireplace. You may relocate this wall switch assembly to a more convenient location such as the side of your mantel or directly onto the wall near the fireplace. To mount the wall switch assembly, you must first cut openings in the mantel or wall where the switch will be located.