INSTALLATION
Continued
3.If not already completed, install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, page 17.
4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.
5.Attach flexible gas line to gas supply. See Con- necting Fireplace to Gas Supply, page 18.
6.Plug electrical cord(s) into electrical outlet installed in step 2.
7.Carefully insert fireplace into rough opening.
8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 36).
9.Check all gas connections for leaks. See Checking Gas Connections, page 19.
10.Install brass trim. See Assembling and Attach- ing Optional Brass Trim, page 23
17 3/4"
33"
35 1/2"
Figure 34 - Rough Opening for Installing
in Wall
393/8"
27 7/8"
35 1/2" 55 5/8"
Figure 35 - Rough Opening for Installing
in Corner
Nails or
Wood
Screws
Nailing
Flanges
Figure 36 - Attaching Fireplace to Wall
Studs
Mantel Clearances for
NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.
NOTICE: If your installation does not meet the minimum clear- ances shown, you must do one of the following:
•raise the mantel shelf to an acceptable height
•remove the mantel shelf
22 | www.desatech.com |