INSTALLATION

Installing Blower Accessory GA3450T in Remote-Ready Models (Cont.)

13

INSTALLATION

Continued

Installing Blower Accessory

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

CAUTION: Verify proper operation after servicing.

Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is built-in, see For Built-In Installation, page 14.

1.Install snap bushings found in hardware kit into both holes in rear of valve cover shield.

2.Make sure the wire harness is firmly connected to the termi- nals on the blower bracket assembly.

3.Note the wire locations on back of AUTO/OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 3 and blue wire from terminal 1. Black wire can remain on middle terminal 2 (see Figure 16).

4.Carefully disconnect green and white wires at their insulated connectors (see Figure 17).

Blower Bracket

Wire

Wiring Routing

Harness

 

5.In top of the fireplace cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket assembly to the outer casing with 4 #10 screws provided (see Figure 16).

6.Route the wire harness through the hole in left side of baffle. Pull wire harness through lower opening on the side of the valve cover shield. (see Figure 16).

7.Insert the 4 wire harnesses into one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield (see Figure 16).

8.Reconnect red wire to switch position 3. Reconnect blue wire to switch position 1. Reconnect green and white wires.

9.Install the switch plate on the valve cover shield with 2 #10 screws provided (see Figure 18). Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 16). Plug fan kit into 120-Volt grounded power supply and test operation. Note: When switch is in the AUTO position, the fan will start after the fireplace has run for a few moments. The fan will continue to run for several moments after the fireplace has been turned off. When switch is in the ON position, the fan will run until turned to OFF. Reinstall upper louver assembly (see Fig- ure 15, page 12) and branch support. Close lower louver door.

Fan Switch

(Auto/Off/On)

1Auto

 

Assembly

Hole in Baffle

 

 

 

Screw

 

Baffle

Blower

 

 

 

Mounting

Holes

 

 

Off

2

 

 

 

3

 

 

 

On

110/115

Red

 

V.A.C.

 

 

 

Black

 

 

 

 

 

 

White

 

 

 

Green

 

Blue Thermostat

Switch

(N.O.)

Blue

Blower

Motor

Red

White

Green

Switch

Power Cord

Snap

 

 

 

Bushing

3

 

 

2

 

 

1

 

 

Switch

Plate Blue

Black Red

Wire Harness

Valve Cover Shield

Lower Louver Door

Figure 16 - Installing Blower Bracket Assembly

Figure 17 - Wiring Diagram For Blower Accessory Standard Installation

Valve Cover

Shield

Switch

Plate

Screw

Figure 18 - Installing Switch Plate to Valve Cover Shield

For morevisit www..com

107032-01F

Page 13
Image 13
Desa VMH26PRA, EFS26PR, VMH10TNB, VMH26NRA installation manual Installing Blower Accessory, Installing Blower Bracket Assembly

VMH10TNB, VMH26NRA, EFS26PR, VMH26PRA specifications

Desa VMH26PRA, EFS26PR, VMH10TNB, and VMH26NRA are notable models in the versatile and efficient heater category that cater to diverse heating needs. Each unit incorporates advanced technologies and features designed to provide reliable warmth while ensuring user convenience.

The Desa VMH26PRA is known for its robust design and impressive performance. Featuring a powerful output, it efficiently warms up spaces making it ideal for larger areas. The model is equipped with a digital thermostat that allows for precise temperature control, providing users the ability to set and maintain their desired warmth effortlessly. Additionally, its safety features, including an automatic shut-off mechanism, ensure peace of mind during operation.

EFS26PR stands out for its energy efficiency and eco-friendly attributes. This model utilizes innovative heating technology that minimizes energy consumption while maximizing output. An integrated fan promotes enhanced air circulation, ensuring that heat disperses evenly throughout the room. The compact design and portability mean it can be easily moved from one location to another, making it a perfect choice for both residential and commercial spaces.

VMH10TNB is notable for its unique combination of performance and aesthetic appeal. This model features a sleek contemporary design that can complement various interior styles. With adjustable heat settings and a user-friendly control panel, this unit aims to provide customized comfort. Moreover, the advanced infrared heating technology utilized in VMH10TNB distributes warmth without compromising air quality, making it a wise choice for those with respiratory sensitivities.

Lastly, the VMH26NRA model is amplified by its high-capacity heating potential. Perfect for colder climates, it boasts a powerful heat output that ensures rapid warmth in a short time. The model is engineered with user-friendly touch controls and a programmable timer that enhances convenience. Safety remains a priority with this heater, which includes a tip-over switch and overheat protection, ensuring secure operation at all times.

In summary, the Desa VMH26PRA, EFS26PR, VMH10TNB, and VMH26NRA all bring distinct features and technologies designed to cater to various heating requirements. Whether looking for advanced safety features, energy efficiency, or stylish design, these models present excellent options for effective heating solutions.