INSTALLATION
Installing Blower Accessory GA3450T in
13
INSTALLATION
Continued
Installing Blower Accessory
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
CAUTION: Verify proper operation after servicing.
Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is
1.Install snap bushings found in hardware kit into both holes in rear of valve cover shield.
2.Make sure the wire harness is firmly connected to the termi- nals on the blower bracket assembly.
3.Note the wire locations on back of AUTO/OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 3 and blue wire from terminal 1. Black wire can remain on middle terminal 2 (see Figure 16).
4.Carefully disconnect green and white wires at their insulated connectors (see Figure 17).
Blower Bracket | Wire | Wiring Routing |
Harness |
|
5.In top of the fireplace cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket assembly to the outer casing with 4 #10 screws provided (see Figure 16).
6.Route the wire harness through the hole in left side of baffle. Pull wire harness through lower opening on the side of the valve cover shield. (see Figure 16).
7.Insert the 4 wire harnesses into one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield (see Figure 16).
8.Reconnect red wire to switch position 3. Reconnect blue wire to switch position 1. Reconnect green and white wires.
9.Install the switch plate on the valve cover shield with 2 #10 screws provided (see Figure 18). Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 16). Plug fan kit into
Fan Switch
(Auto/Off/On)
1Auto
| Assembly | Hole in Baffle | |
|
|
| |
Screw |
| Baffle | Blower |
|
|
| Mounting |
Holes
|
| Off | 2 |
|
|
| 3 |
|
|
| On |
110/115 | Red | ||
| V.A.C. |
| |
|
| Black |
|
|
|
| |
|
| White |
|
|
| Green |
|
Blue Thermostat
Switch
(N.O.)
Blue
Blower
Motor
Red
White
Green
Switch | Power Cord | Snap |
| ||
|
| Bushing |
3 |
|
|
2 |
|
|
1 |
|
|
Switch
Plate Blue
Black Red
Wire Harness
Valve Cover Shield
Lower Louver Door
Figure 16 - Installing Blower Bracket Assembly
Figure 17 - Wiring Diagram For Blower Accessory Standard Installation
Valve Cover
Shield
Switch
Plate
Screw
Figure 18 - Installing Switch Plate to Valve Cover Shield
For morevisit www..com