Desa CGEF26B, ES301, CGEF32D Installation, Continued, New Construction or Renovation, Framing

Models: CGEF32D VEF32B CGEF26B ES301 VEF26B

1 20
Download 20 pages 10.82 Kb
Page 6
Image 6
New Construction or Renovation

Installation

Continued

Note: It is strongly advised that you hire a qualified professional to undertake this step in order to prevent personal injury. Once flue is capped, chimney is no longer suitable for wood burning.

Note: Do not install this unit into a fireplace that is prone to dampness; the area of instal- lation must be dry.

4.Plan the power supply. If an existing grounded outlet is near fireplace, power cord can run along front of fireplace. If cord is not long enough to reach outlet, a grounded extension cord minimum AWG No. 14 and rated to a minimum of 1875 watts, may be used. If you plan to cut or drill a hole in existing fireplace for wiring, it is best to hire a professional to do this step in order to prevent personal injury. To reduce the risk of fire, do not run power cord under rugs, carpets, etc. Arrange power supply cord away from high traffic areas where it may pose a tripping hazard.

FramingWARNING: The solid fuel/gas fireplace has been converted for use with an electric insert and cannot be used for original fuels unless all original parts have been replaced and the fireplace has been reapproved by the au- thority having jurisdiction.

New Construction or Renovation

1.Select a location at least 3 feet (0.9 m) away from combustible materials such as curtains or drapes, furniture, bedding, paper, etc.

2.Mark desired location on floor and store unit in a safe, dry and dust free location.

3.Frame in an opening leaving at least 1/4" (6 mm) around the edge of the unit (see Framing). Any new wiring must be done in compliance with local and national codes and other applicable regulations in order to reduce the risk of fire, electric shock or other injuries. Therefore, it strongly recommended that you hire a professional to complete any such work.

4.Plan you power supply route. See step 4 of Existing Fireplace Installation.

Framing

Figure 4, shows a typical framing of this heater using combustible materials. All required clearances to combustibles must be adhered to. Header height is measured from the base of the heater.

Tools and building supplies required for installation:

Saw

• Square

Pliers

Gloves

Hammer

• Level

Phillips screwdriver

Surround

Framing materials

Electric drill/bits

Tape measure

Wall-finishing materials

Caulking material

Header

Height

Length

Depth

Model Depth Length HeaderHeight

26"

9.75"

27"

26"

32"

10.5"

34"

32"

0.75"- 0.50"

Note: The height that a combustible mantel is fitted above the heater is dependent on the height of the front selected. The minimum height is 1" above the front.

Figure 4 - Framing Heater for New
Construction/Renovation

www.desatech.com120927-54B

Page 6
Image 6
Desa CGEF26B Installation, Continued, New Construction or Renovation, Framing Heater for New, Construction/Renovation