Desa MSBVBP Installing Vent System In A Chase, Checking Vent Capacity, Chimneys, Relining Systems

Models: MSBVBN MSBVBP

1 32
Download 32 pages 52.32 Kb
Page 10
Image 10
INSTALLING VENT SYSTEM IN A CHASE

SUN VALLEY STOVE COMPANY

B-VENT FREESTANDING FIREPLACE

VENTING INSTALLATION

Continued

INSTALLING VENT SYSTEM IN A CHASE

A chase is a vertical boxlike structure built to enclose venting that runs along the out- side of a building. A chase is not required for such venting.

NOTICE: Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for the re- quirements of local building codes. You must follow all local building codes.

Note: When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially im- portant in cold climates. Minimum clear- ance between vent pipes and combustible materials such as insulation is 1".

CHECKING VENT CAPACITY

Complete all gas piping, electrical, and vent connections. After adjusting the fireplace and lighting the main burners, allow a couple of minutes for warm-up. Hold a lighted match just under the rim of the draft hood relief opening. Proper venting will draw the flame toward or into the draft hood. Im- proper venting, indicated by escape or spill- age of burned gas, will cause match to flicker or go out. Smoke from a cigarette will also be pulled into the draft hood if the vent is drawing properly.

CHIMNEYS

Complete familiarity with chimney con- dition, height, size, clearance to combus- tibles and other factors is essential.

NOTICE: Consult the authority having jurisdiction in your area regarding masonry chimney vent- ing applications.

NOTICE: A complete chimney inspection by a qualified person should be performed.

Appliances using B-vent connectors to vent into a masonry or factory-built chimney should not exceed 1 1/2 feet in length for every inch of connector diam- eter (3" vent connector has a maximum 4 1/2 foot length; 5" connector has maxi- mum 7 1/2 foot length).

Oversized chimneys should be relined with appropriate listed relining systems.

Cleanout access may be required.

RELINING SYSTEMS

Suitability and approval of relining ma- terials should be determined.

Condition, size, height, and termina- tion of the chimney to be relined must be determined.

No substitution of components should be made.

Joints and connectors should be made according to manufacturer’s instructions.

NOTICE: Consult the authority having jurisdiction in your area regarding listed chimney liner venting applications.

CHECKING VENT CAPACITY WARNING: Operation of im- properly installed and maintained venting system could result in serious injury, property damage, or loss of life.

 

Figure 27 - Typical Straight Installation

 

with Listed Chimney Liner

Figure 25 - Test for Proper Venting

Figure 26 - Straight Installation into

Masonry Chimney