INSTALLING

INSTALLING

INSTALLATION CLEARANCES

Continued

 

WARNING ICONG 001WARNING

Maintain the minimum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Wall and Ceiling Clearances (see Figure 7)

A.Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

Note:

42"

Clearances are

the same if

 

using optional

 

cabinet mantel

MINIMUM CLEARANCE

or built-in

installation.

Side Wall - 16 "

 

Ceiling - 42"

 

Floor - 0"

16"

Figure 7 - Minimum Clearance to Wall and Ceiling

CONVENTIONAL FIREPLACE INSTALLATION

Conventional installation of this fireplace involves installing fireplace along with the cabinet mantel with hearth base accessories against a wall in your home. Follow the instructions below to install the fireplace in this manner.

WARNING

WARNING ICON

G 001

For conventional installation, it is recommended you use the cabinet mantel or hearth base specified in this manual. Surface clearances may not be sufficient with other cabinet mantels and hearth bases. This may create a fire hazard. See Accesso- ries, page 31 for correct cabinet mantel and hearth base.

Note: The instructions below show installation using the cabinet mantel and hearth base accessories. The hearth base accessory is optional for this installation. You can install fireplace and cabinet mantel directly on the floor.

1.Assemble cabinet mantel and hearth base. Assembly instructions are included with each accessory.