Desa UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE Trouble, Shooting, Continued, Connections, page

Models: UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE

1 36
Download 36 pages 49.36 Kb
Page 29
Image 29
TROUBLE-

TROUBLE-

WARNING ICONG 001 WARNING

SHOOTING

If you smell gas

Continued

• Shut off gas supply.

• Do not try to light any appliance.

 

 

• Do not touch any electrical switch; do not

 

use any phone in your building.

 

• Immediately call your gas supplier from a

 

neighbor’s phone. Follow the gas supplier’s

 

instructions.

 

• If you cannot reach your gas supplier, call

 

the fire department.

 

 

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

 

OBSERVED

POSSIBLE

 

 

 

 

 

 

 

 

 

PROBLEM

CAUSE

 

 

REMEDY

 

 

 

 

 

 

 

 

 

 

 

 

 

Fireplace produces a

1.

Metal expanding while

1.

This is common with

 

 

 

 

clicking/ticking noise

 

heating or contracting

 

most fireplaces. If noise

 

just after burners are

 

while cooling

 

 

is excessive, contact

 

 

 

 

lit or shut off

 

 

 

 

 

qualified service person

 

 

 

 

 

 

 

 

 

 

 

 

Fireplace produces

1.

Fireplace

burning

va-

1.

Open window and

 

 

 

 

unwanted odors

 

pors from

paint,

hair

 

ventilate room. Stop

 

 

 

 

 

 

spray, glues, cleaners,

 

using odor causing

 

 

 

 

 

 

chemicals, new carpet,

 

products while fireplace

 

 

 

etc. (See IMPORTANT

 

is running

 

 

 

 

 

 

statement above)

 

 

 

 

 

 

 

 

 

2.

Gas leak. See Warn-

2.

Locate and correct

all

 

 

 

ing statement at

 

 

leaks (see Checking Gas

 

 

 

top of page

 

 

Connections, page 18)

 

 

 

 

 

 

 

 

 

 

Fireplace shuts off in

1.

Not enough fresh air is

1.

Open window and/or

 

 

 

 

use (ODS operates)

 

available

 

 

 

door for ventilation

 

 

 

 

 

2.

Low line pressure

 

2.

Contact local natural

 

 

 

 

 

 

 

 

 

 

gas company

 

 

 

 

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

 

 

 

 

clogged

 

 

 

Cleaning and Mainte-

 

 

 

 

 

 

 

 

 

 

nance, page 26)

 

 

 

 

 

 

 

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct

all

 

control knob is in

 

ing statement at

 

 

leaks (see Checking Gas

 

OFF position

 

top of page

 

 

Connections, page 18)

 

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

 

 

 

 

 

 

Gas odor during

1.

Foreign matter be-

 

1.

Take apart gas tubing

 

 

 

 

combustion

 

tween control valve

 

and remove foreign

 

 

 

 

 

 

and burner

 

 

matter

 

 

 

 

 

2.

Gas leak. See Warn-

2.

Locate and correct

all

 

 

 

ing statement at

 

 

leaks (see Checking Gas

 

 

 

top of page

 

 

Connections, page

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

18)

 

101742

Page 29
Image 29
Desa UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE Trouble, Shooting, Continued, leaks see Checking Gas, Connections, page