TROUBLE- | WARNING ICONG 001 WARNING | |
SHOOTING | If you smell gas | |
Continued | • Shut off gas supply. | |
• Do not try to light any appliance. | ||
| ||
| • Do not touch any electrical switch; do not | |
| use any phone in your building. | |
| • Immediately call your gas supplier from a | |
| neighbor’s phone. Follow the gas supplier’s | |
| instructions. | |
| • If you cannot reach your gas supplier, call | |
| the fire department. | |
|
|
IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
| OBSERVED | POSSIBLE |
|
|
|
|
|
|
|
| |
| PROBLEM | CAUSE |
|
| REMEDY |
|
|
| |||
|
|
|
|
|
|
|
|
| |||
| Fireplace produces a | 1. | Metal expanding while | 1. | This is common with |
|
|
| |||
| clicking/ticking noise |
| heating or contracting |
| most fireplaces. If noise | ||||||
| just after burners are |
| while cooling |
|
| is excessive, contact |
|
|
| ||
| lit or shut off |
|
|
|
|
| qualified service person | ||||
|
|
|
|
|
|
|
|
|
|
| |
| Fireplace produces | 1. | Fireplace | burning | va- | 1. | Open window and |
|
|
| |
| unwanted odors |
| pors from | paint, | hair |
| ventilate room. Stop |
|
|
| |
|
|
| spray, glues, cleaners, |
| using odor causing |
|
|
| |||
|
|
| chemicals, new carpet, |
| products while fireplace | ||||||
|
|
| etc. (See IMPORTANT |
| is running |
|
|
| |||
|
|
| statement above) |
|
|
|
|
|
|
| |
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct | all | |||||
|
|
| ing statement at |
|
| leaks (see Checking Gas | |||||
|
|
| top of page |
|
| Connections, page 18) | |||||
|
|
|
|
|
|
|
|
| |||
| Fireplace shuts off in | 1. | Not enough fresh air is | 1. | Open window and/or |
|
|
| |||
| use (ODS operates) |
| available |
|
|
| door for ventilation |
|
|
| |
|
| 2. | Low line pressure |
| 2. | Contact local natural |
|
|
| ||
|
|
|
|
|
|
| gas company |
|
|
| |
|
| 3. | ODS/pilot is partially | 3. | Clean ODS/pilot (see |
|
|
| |||
|
|
| clogged |
|
|
| Cleaning and Mainte- |
|
|
| |
|
|
|
|
|
|
| nance, page 26) |
|
|
| |
|
|
|
|
|
|
|
| ||||
| Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct | all | |||||
| control knob is in |
| ing statement at |
|
| leaks (see Checking Gas | |||||
| OFF position |
| top of page |
|
| Connections, page 18) | |||||
|
| 2. | Control valve defective | 2. | Replace control valve | ||||||
|
|
|
|
|
|
|
|
|
| ||
| Gas odor during | 1. | Foreign matter be- |
| 1. | Take apart gas tubing |
|
|
| ||
| combustion |
| tween control valve |
| and remove foreign |
|
|
| |||
|
|
| and burner |
|
| matter |
|
|
| ||
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct | all | |||||
|
|
| ing statement at |
|
| leaks (see Checking Gas | |||||
|
|
| top of page |
|
| Connections, page |
|
|
|
| |
|
|
|
|
|
| 29 | |||||
|
|
|
|
|
|
| 18) |
|
101742