Desa UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE Technical Service Service Hints

Models: UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE

1 36
Download 36 pages 49.36 Kb
Page 30
Image 30
TECHNICAL

TECHNICAL

SERVICE

SERVICE

HINTS

REPLACEMENT PARTS

SPECIFICATIONS

30

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

When gas pressure is too low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

When gas quality is bad

pilot will not stay lit

burners will produce flames and soot

fireplace will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

When calling DESA International, have ready

your name

your address

model number of your fireplace

how fireplace was malfunctioning

type of gas used (propane or natural gas)

purchase date

Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for informa- tion.

When calling DESA International, have ready

model number of your fireplace

the replacement part number

BTU (Variable)

20,000/26,500

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Regulator

3.5" W.C.

Setting

 

Inlet Gas

 

Pressure (in. of water)

 

Maximum

10.5"

Minimum

5"

Shipping Weight

89 lbs.