Desa UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE Operating, Fireplace, Notice, Continued, Pilot

Models: UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE

1 36
Download 36 pages 49.36 Kb
Page 23
Image 23
OPERATING
C-clockwise

OPERATING

 

 

LIGHTING INSTRUCTIONS

 

 

 

 

 

 

FIREPLACE

 

 

 

 

 

 

 

 

 

 

 

 

WARNING ICONG 001WARNING

 

Continued

 

 

 

 

You must operate this fireplace with the fireplace

 

 

 

 

 

 

screen in place. Make sure fireplace screen is installed

 

 

 

before running fireplace.

 

 

 

 

 

 

 

NOTICE

During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information on page 22.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise

Clockwise

to the OFF position.

 

 

Control Knob

Ignitor Button

Figure 26 - Control Knob and Ignitor Button Location

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

5. Turn control knob counterclockwise LIGHTING INSTRUCTIONS to the PILOT position. Press in control knob for five (5) seconds (see Figure 26, above).

Note: If running fireplace for first time, there will be air in gas line. You may need to press in control knob for 30 seconds or longer. This will allow air to bleed from the gas system.

6.Continue pressing control knob in. Press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 24.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 6. This fireplace has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Thermocouple

Ignitor Electrode

Pilot Burner

Continued

Figure 27 - Pilot