Desa VDCFRPA, VDCFTPA, VDCFRNA Continued, For Built-In Installation, Extension Cord

Models: VDCFRPA VDCFTPA

1 44
Download 44 pages 490 b
Page 15
Image 15
For Built-In Installation

INSTALLATION

Continued

For Built-In Installation

Extension Cord WARNING: A licensed elec- trician must connect the wiring harness to electrical supply following all local codes. Electri- cian must provide a clamp on the box cover to secure the wiring. Wiring should be routed through the bushing in the hole on the outer casing of fireplace.

1.Install snap bushing from blower kit into one hole on rear of remote/blower bracket (see Figure 17). The other hole is for a strain relief clamp (not supplied) to secure incoming electrical supply.

2.Follow steps 2 through 6 in Installing Blower Accessory, page 14.

3.A licensed electrician must follow the wiring diagram to connect incoming electrical supply to fan kit wiring harness (see Figure 18).

4.Plug power cord to outlet receptacle (not provided) as shown in Figure 17. Wind the extra power cord and tie with plastic wire strap (see Figure 17). Set power cord bundle between the remote/blower bracket and outer casing, away from the burner.

5.Test to make sure blower is working properly.

6.Reinstall upper louver beginning with bottom screws (see Figure 11, page 12) and close lower louver.

Extension Cord

 

 

 

 

 

 

 

 

 

 

Use extension cord if needed. The cord must have

a three-prong, grounding plug and a three-hole re-

ceptacle. Make sure cord is in good shape. It must

be heavy enough to carry the current needed. An

undersized cord will cause a drop in line voltage.

This will result in loss of power and overheating. Use

a No. 16 AWG cord for lengths less than 50 feet.

 

Fan Switch

 

 

 

 

 

 

 

 

(Auto/Off/On)

 

 

 

 

 

 

 

 

 

1 Auto

 

 

 

 

 

 

 

 

Off

2

 

 

 

 

 

 

 

 

 

 

 

3

Blue

 

Thermostat

 

 

 

On

 

 

 

Switch

 

 

 

 

 

 

(N.O.)

110/115

 

 

Red

 

 

 

 

Blue

V.A.C.

 

 

 

 

 

Blower

 

Black

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

Red

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

 

 

White

 

 

Green

 

 

 

 

 

 

Green

Figure 18 - Wiring Diagram For Blower

Accessory Built-In Installation

Blower Bracket

Wire Harness

 

Assembly

 

Screw

 

Power Cord

Switch

Outlet Receptacle (not included) Figure 18 - Wiring Diagram For Blower

3 2 1

Switch

Plate

Plastic Wire Strap

Wire Harness

 

Clamp Connector (not included)

Remote/ Blower Bracket

Lower Louver Door

Figure 17 - Installing Blower Bracket Assembly

113133-01B

www.desatech.com

15

Page 15
Image 15
Desa VDCFRPA, VDCFTPA, VDCFRNA Continued, For Built-In Installation, Extension Cord, Installing Blower Bracket Assembly