Desa VDCFRPA, VDCFTPA, VDCFRNA installation manual Installation

Models: VDCFRPA VDCFTPA

1 44
Download 44 pages 490 b
Page 9
Image 9
INSTALLATION

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

Manual background WARNING: A qualified ser- vice person must install fire- place. Follow all local codes.

Manual background WARNING: Never install the fireplace

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 36 inches from the front, top or sides of the fireplace

as a fireplace insert

in high traffic areas

in windy or drafty areas

Manual background WARNING: Never install in a bedroom or bathroom.Any heat- ing product with a Btu/Hr rating over 10,000 cannot be used in a bedroom.

Manual background CAUTION: This fireplace cre- ates warm air currents. These currents move heat to wall sur- faces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impurities (such as, but not limited to, tobacco smoke, aromatic candles, clean- ing fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free fireplaces add moisture to the air. Although this is beneficial, installing fire- place in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6.

Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.

Note: When installing fireplace directly on carpet- ing, tile or other combustible material, other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth of the fireplace.

Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fire- place Installation, page 11).

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

Manual background WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

113133-01B

www.desatech.com

9

Page 9
Image 9
Desa VDCFRPA, VDCFTPA, VDCFRNA installation manual Installation