Desa VDCFTPA, VDCFRPA, VDCFRNA Continued, Installation Items, Fireplace Clearances, Ceiling

Models: VDCFRPA VDCFTPA

1 44
Download 44 pages 490 b
Page 10
Image 10
INSTALLATION ITEMS

INSTALLATION

Continued

INSTALLATION ITEMS

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer, for propane/LP units only)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection*

ground joint union

sediment trap

tee joint

pipe wrench

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 40.

Note: If desired, purchase a four-sided perimeter trim kit for built-in installations. See Accessories, page 40.

FIREPLACE CLEARANCES

FIREPLACE CLEARANCES WARNING: Maintain the minimum clearances shown in Figure 6. If you can, provide greater clearances from floor, ceiling and joining wall.

If your fireplace is to be used with an optional mantel, the installation instructions included with your mantel shows an CSA approved method of attaching the fireplace/mantel system to a wall. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual. Purchase the optional mantel from your dealer (see Acces- sories, page 40).

If your fireplace is to be recessed into the wall, see Built-In Fireplace Installation on page 11 to secure your fireplace into the wall.

Minimum Clearances For Side CAUTION: If you install the fireplace in a home garage

fireplace pilot and burner must be at least 18 inches above floor.

locate fireplace where moving vehicle will not hit it.

For convenience and efficiency, install fireplace

where there is easy access for operation, inspec- tion and service

in coldest part of room

An optional blower kit is available from your dealer. See Accessories, page 40. If planning to use blower, follow instructions provided with blower for power source.

Minimum Clearances For Side

Combustible Material, Side Wall and

Ceiling

A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 6.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 6).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 36 inches.

C.For mantel clearances, see Figure 10 on page 12.

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS

Top

Left and

Bottom

 

Right Sides

and Rear

36"

6"

0"

 

Example

 

 

 

*

*Minimum 16 inches from Side Wall

Figure 6 - Minimum Clearance for

Combustible to Wall

10

www.desatech.com

113133-01B

Page 10
Image 10
Desa VDCFTPA Continued, Installation Items, Fireplace Clearances, Minimum Clearance To Combustible Materials, Ceiling