Gas leak. See Warning

TROUBLESHOOTING

Continued

Manual background WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Fireplace produces unwanted 1.

Fireplace burning vapors from

odors

paint, hair spray, glues, clean-

 

ers, chemicals, new carpet,

 

etc. (See IMPORTANT state-

 

ment above)

2.

Low fuel supply (propane/LP

 

only)

3.

Gas leak. See Warning state-

 

ment at top of page

1.Open window to ventilate room. Stop using odor caus- ing products while fireplace is running

2.Refill supply tank (propane/LP only)

3.Locate and correct all leaks (see Checking Gas Connec- tions, page 17)

Fireplace shuts off in use (ODS

1. Not enough fresh air is

1.

Open window and/or door for

operates)

 

available

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

3.

O D S / pi l o t i s p a rt i a l l y

 

pane/LP gas company

 

3.

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 27)

 

 

 

 

Gas odor even when control

1. Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

2.

Control valve defective

 

tions, page 17)

 

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between con-

 

 

trol valve and burner

 

2.

Gas leak. See Warning

 

 

statement at top of page

1.Take apart gas tubing and remove foreign matter

2.Locate and correct all leaks (see Checking Gas Connec- tions, page 17)

32