VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Termination (Cont.)

VENTING INSTALLATION

INSTRUCTIONS

Continued

Venting with One 90° Elbow

Vertical (V)

Horizontal (H)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

45° Elbow

Note: Install restrictor

 

into inner collar of

 

fireplace as shown.

Figure 22 - Vertical Venting Configuration Using One 90° Elbow

(Vertical Round High Wind Termination Shown)

Venting with Two 90° Elbows

45° Elbow

 

 

Vertical (V1)

Horizontal (H)

 

5' min.

6' max.

 

6' min.

12' max.

 

7' min.

18' max.

 

8' min.

20' max.

 

Vertical Venting

V = 40' max.

Note: Install restrictor into inner collar of fireplace as shown.

Note: Install restrictor into inner collar of fireplace as shown.

45° Elbow

Figure 24 - Vertical Venting Configuration With No Horizontal Run (Vertical Round High Wind Termination Shown)

Note: Vertical (V1) + Vertical (V2) = 40' max.

Figure 23 - Vertical Venting Configuration Using Two 90° Elbows (Vertical Round High Wind Termination Shown)