FIREPLACE INSTALLATION

Installing Optional Blower Accessory (Cont.)

17

FIREPLACE INSTALLATION

Continued

5.Mount the speed control box against the mounting plate provided in the lower fireplace cavity by placing the plastic control shaft forward through the round hole (see Figure 26, page 16).

Model BKT Installation

Note: When installing the BKT thermostatically-controlled blower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed.

1.Place the green ground wire with ring terminal between the bottom hole on the thermal switch bracket and the top ear hole on the blower assembly. Insert the phillips screw into all three pieces and tighten securely (see Figure 28).

2.Connect wire harness and power cord terminals. Connect the blue jumper wire to the blower motor terminal and the right side terminal of the thermal switch. Connect the black wire to the left side of the thermal switch and the white wire to the other remaining blower motor terminal.

Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely.

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermo- disc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 28, in order to sense temperature and properly operate. The blower will be held in position against the back wall by the magnets incorporated onto the blower housing (see Figure 28).

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and thermal switch and that the screw for the thermodisc bracket and green ground wire is tight.

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against mounting plate. Place control knob provided on shaft (see Figure 26, page 16).

7.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel.Also double check all wire leads and make sure wire routing is not pinched or in a precarious position. Correct accordingly.

8.Turn on power to duplex outlet if previously turned off per the warning in column 1, page 16.

9.Plug in blower power cord to duplex outlet.

10.The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up. The blower speed can be adjusted by rotating the control knob. To turn off, turn knob fully counterclock- wise until it clicks off. If the blower is ON and has been running with the fireplace operating, the blower will continue to run for a short time after the fireplace has been turned off. As the thermal switch cools down, the blower shuts down automatically.

11.Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27, page 16).

Blower Wiring Diagram

CAUTION: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause

improper and dangerous operation. Verify proper

operation after servicing.

Power Cord

Thermal

Switch

Bracket

Black

Wire

Phillips Screw

Thermal Switch

White Wire

 

Blue Wire

Magnetic

 

Strips

Air Flow

 

Direction

 

Ring Terminal on Green Wire

Air Flow Direction

 

 

Variable

Fan Switch

 

Fan Switch

 

 

 

(N.O.)

 

Off

1

Black

 

2

 

 

 

 

On

 

110/115

 

 

Blue

V.A.C.

Black

 

 

 

 

Blower

 

 

 

 

White

 

Motor

 

Green

 

 

 

 

Magnets

 

Route BKT

 

Figure 29

- Blower Wiring Diagram for Thermostat-Controlled Models

Blower Through

Thermodisc

 

 

This Area

 

 

 

 

 

Side View Firebox Bottom

Blower

 

Location

 

Figure 28 - Blower Model BKT

 

 

 

116647-01A

www.desatech.com

Page 17
Image 17
Desa (V)T32EN-A Series, (V)T32EP-A Series Fireplace Installation, Model BKT Installation, Blower Wiring Diagram