Pressure Testing Fireplace Gas Connections

1.

Open equipment shutoff valve (see Figure 33, page 20).

2.

Open propane/LP supply tank valve for propane/LP fireplace

 

or main gas valve located on or near gas meter for natural gas

 

fireplace.

3.

Make sure control knob of fireplace is in the OFF position.

4.

Check all joints from equipment shutoff valve to gas valve (see

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip (see Figure 37).

4.Attach the terminal wires to the battery.

5.Connect wires from receiver to TH and TPTH to control valve (see Figure 38).

6.Replace the switch bracket.

 

Figure 34 for propane/LP or Figure 35 for natural gas, page 20).

 

Apply noncorrosive leak detection fluid to all joints. Bubbles

 

forming show a leak. Correct all leaks at once.

5.

Light fireplace (see Operating Fireplace, page 25). Check all

 

other internal joints for leaks.

6.

Turn off fireplace (see To Turn Off Gas to Appliance, page 25).

INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2

1. Connect one terminal of 25 ft. wire for the wall switch to the

Receiver

9-Volt Alkaline Battery

Terminal

Wires

Battery Clip

Figure 37 - Attaching Alkaline Battery to Receiver

To Optional

Remote

Accessory

Figure 38 - Connecting Remote Accessory to Control Valve

 

TPTH terminal on the valve. Connect remaining wire terminal

 

to the TH terminal on the valve. Make sure that the wire termi-

 

nals are in the positions on the unit as pictured in Figure 36. If

 

wires are not connected as shown the switch will not work.

2.

Route the 25 ft. wire through openings provided on the sides of

 

the burner system to a convenient location to mount your switch.

3.

Connect one bare wire end to each of the terminals of the

 

GWMS2 wall switch.

4.

Install the wall switch and cover in the wall.

To Wall Switch

Accessory

Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote control unit.

 

Battery Cover

Remote

Terminal

 

 

Control Unit

Wires

 

 

9-Volt Alkaline Battery

Battery

Housing

Figure 36 - Connecting Wall Swith to Control Valve

INSTALLING OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL - (C)GHRC AND (C)GHRCTA SERIES

NOTICE: Use only alkaline batteries (not included).

Figure 39 - Installing Alkaline Battery in Hand-Held Remote Control Unit ([C]GHRC)

 

Terminal

9-Volt

Wires

 

Battery

 

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver.

Battery Cover

Remote

Control

Unit

Figure 40 - Installing Battery in Hand-Held Remote Control Unit

([C]GHRCTA Series)

For morevisit www..com

111250-01C

Page 21
Image 21
Desa (V)T36NA SERIES Installing Optional Wall Mount Switch GWMS2, Pressure Testing Fireplace Gas Connections

(V)T36NA SERIES specifications

The Desa (V)T36NA SERIES represents a significant advancement in the realm of energy-efficient heating solutions, combining cutting-edge technologies with user-centric design. This series is renowned for its ability to deliver reliable heating performance while ensuring a minimal environmental impact. One of the standout features of the Desa (V)T36NA SERIES is its innovative use of high-efficiency ceramic burners. These burners not only provide superior heat output but also enhance the overall thermal efficiency of the unit, ensuring that energy consumption is kept to a minimum.

This series is equipped with a sleek, contemporary design that seamlessly fits into various home interiors. The aesthetic appeal is complemented by a range of customizable options, including different finishes and decorative elements, allowing homeowners to select a model that matches their personal style and home decor. Another notable aspect of the Desa (V)T36NA SERIES is its advanced thermostat control technology. This feature enables precise temperature regulation, ensuring consistent comfort while optimizing energy usage.

Safety is a paramount concern in the design of the Desa (V)T36NA SERIES. Each unit comes with multiple safety features, including an automatic shut-off system and a protective glass front, which provides a barrier against accidental contact. This focus on safety does not detract from the performance; rather, it enhances the user experience, providing peace of mind for families.

In terms of installation, the Desa (V)T36NA SERIES offers flexibility with venting options that cater to various home layouts. This adaptability simplifies the installation process and makes it easier to integrate the heating system into existing structures. Furthermore, these units are designed with ease of maintenance in mind, featuring accessible components that allow for straightforward servicing.

Another characteristic that sets the Desa (V)T36NA SERIES apart is its commitment to sustainability. Utilizing environmentally friendly materials and designs, this series minimizes emissions and energy consumption, aligning with modern environmental standards. Overall, the Desa (V)T36NA SERIES represents an optimal choice for discerning homeowners seeking an efficient, stylish, and reliable heating solution. With its impressive combination of features, technologies, and characteristics, this series is poised to redefine comfort and sustainability in home heating.