8

VENTING INSTALLATION INSTRUCTIONS

Installation Planning

VENTING INSTALLATION INSTRUCTIONS

Continued

2.Direct vent pipe sections and components are designed with special twist-lock connections.

Twist-Lock Procedure: The female ends of the pipes have locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes. Push pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked (see Figure 8). Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose.

3.Use a 45° elbow to connect venting system to fireplace flue col- lar. The elbow is designed to be twist-locked onto the flue collar as described in step 2. IMPORTANT: Do not attempt to alter the configuration of the elbow by cutting, twisting, bending, etc.

4.Assemble the desired combination of pipe and elbows to the fireplace. If there are long portions of venting run, pre-as- sembled pipe sections may be installed as subassemblies for convenience.

5.Carefully determine the location where the vent pipe assembly will penetrate the outside wall. The center of the hole should line up with the center-line of the horizontal vent pipe. Mark the wall for a 10" x 10" square hole. Cut and frame the square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, such as masonry block or concrete, a 7 3/4" hole with zero clearance is acceptable (see Figure 9).

WARNING: Do not recess vent termination into any wall. This will cause a fire hazard.

6.Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 7 3/4" round hole and attach to the exte- rior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around the outside edges to make a seal be- tween it and the outside wall. Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

Male

Slots

Female

Locking

Lugs

Figure 8 - Vent Pipe Connections

Vent Opening

 

 

Combustible Wall

10" Inside Framing

 

 

10"

 

(254mm)

(254mm)

 

 

10"

 

 

(254mm)

 

 

 

(Framing

Vent Opening

 

Detail)

 

 

Noncombustible Wall

 

 

7 3/4"

 

 

(197mm)

 

 

 

 

Center

 

 

of Hole

Figure 9 - Vent Opening Requirements

For..com

111250-01C

Page 8
Image 8
Desa (V)T36NA SERIES installation manual Vent Pipe Connections

(V)T36NA SERIES specifications

The Desa (V)T36NA SERIES represents a significant advancement in the realm of energy-efficient heating solutions, combining cutting-edge technologies with user-centric design. This series is renowned for its ability to deliver reliable heating performance while ensuring a minimal environmental impact. One of the standout features of the Desa (V)T36NA SERIES is its innovative use of high-efficiency ceramic burners. These burners not only provide superior heat output but also enhance the overall thermal efficiency of the unit, ensuring that energy consumption is kept to a minimum.

This series is equipped with a sleek, contemporary design that seamlessly fits into various home interiors. The aesthetic appeal is complemented by a range of customizable options, including different finishes and decorative elements, allowing homeowners to select a model that matches their personal style and home decor. Another notable aspect of the Desa (V)T36NA SERIES is its advanced thermostat control technology. This feature enables precise temperature regulation, ensuring consistent comfort while optimizing energy usage.

Safety is a paramount concern in the design of the Desa (V)T36NA SERIES. Each unit comes with multiple safety features, including an automatic shut-off system and a protective glass front, which provides a barrier against accidental contact. This focus on safety does not detract from the performance; rather, it enhances the user experience, providing peace of mind for families.

In terms of installation, the Desa (V)T36NA SERIES offers flexibility with venting options that cater to various home layouts. This adaptability simplifies the installation process and makes it easier to integrate the heating system into existing structures. Furthermore, these units are designed with ease of maintenance in mind, featuring accessible components that allow for straightforward servicing.

Another characteristic that sets the Desa (V)T36NA SERIES apart is its commitment to sustainability. Utilizing environmentally friendly materials and designs, this series minimizes emissions and energy consumption, aligning with modern environmental standards. Overall, the Desa (V)T36NA SERIES represents an optimal choice for discerning homeowners seeking an efficient, stylish, and reliable heating solution. With its impressive combination of features, technologies, and characteristics, this series is poised to redefine comfort and sustainability in home heating.