Desa (V)T36NA SERIES High Altitude Installation, Venting Installation Instructions, Continued

Models: (V)T36NA SERIES

1 38
Download 38 pages 46.68 Kb
Page 15
Image 15
Vertical Venting

VENTING INSTALLATION INSTRUCTIONS

Continued

Vertical Venting

V = 40' max.

Note: Install restrictor into inner collar of fireplace as shown.

45° Elbow

VENTING INSTALLATION INSTRUCTIONS

15

Installation for Vertical Termination (Cont.)

High Altitude Installation

 

 

 

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been tested and approved for elevations from 0-2000 feet (USA) and elevations from 0-4500 feet (Canada) .

When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas company to help determine the proper orifice for your location.

For assistance with any high altitude installation contact DESA’s Customer Service Department at 1-866-672-6040.

Figure 24 - Vertical Venting Configuration With No Horizontal

Run (Vertical Round High Wind Termination Shown)

HIGH ALTITUDE INSTALLATIONFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111250-01C

Page 15
Image 15
Desa (V)T36NA SERIES High Altitude Installation, Venting Installation Instructions, Continued, Vertical Venting