OPERATING HEATER

Blue Flame

Continued

THERMOSTATIC "ROOM" FUNCTION

Thermocouple

Pilot Burner

Setting Desired Room Temperature This remote control system can be thermostati- cally controlled when the remote control is in the thermostatic mode. The word ROOM must be displayed on the screen.

1.Press MODE button on remote control until ROOM appears. This sets the remote to the thermostat mode.

2.Press and hold the SET button until the desired temperature is displayed. The numbers will increase from 45° to 99° then restart over at 45°. After releasing the SET button, the set room temperature will dis- play for 3 seconds, then default to display the room temperature.

Changing Set Temperature

1.Follow step two under Setting Desired Room Temperature above.

2.Press the MODE button to disengage the thermo mode. The word ROOM does not display when thermostatic mode is not in operation.

INSPECTING HEATER

Check pilot flame pattern and burner flame pat- tern often.

PILOT FLAME PATTERN

Figure 20 shows a correct pilot flame pattern. Figure 21 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 21

turn heater off (see To Turn Off Gas to Appliance, page 14)

see Troubleshooting, page 17

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Figure 20 - Correct Pilot Flame Pattern

 

Yellow Flame

Thermocouple

Pilot Burner

 

Figure 21 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 22 shows a correct and incorrect burner flame

pattern. If burner flame pattern is incorrect

turn heater off (see To Turn Off Gas to Appli- ance, page 14)

see Troubleshooting, page 17

Correct

Incorrect

Flame

Flame

Pattern

Pattern

Figure 22 - Burner Operation

113261-01C

www.desatech.com

15

Page 15
Image 15
Desa VTN25R, VTP22R Inspecting Heater, Pilot Flame Pattern, Burner Flame Pattern, Thermostatic Room Function