 WARNING: If you smell gas

TROUBLESHOOTING

Continued

Manual background WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Remote does not function

1.

Battery is not installed or bat-

1.

ReplaceAAbatteries in receiver

 

 

ter power is low

 

and remote hand set

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaner, etc., may turn into

 

cleaners or similar products

 

 

white powder residue

 

 

 

 

 

 

 

Heater produces unwanted

1.

Heater burning vapors from

1.

Ventilate room. Stop using

odors

 

paint, hair spray, glues, etc.

 

odor causing products while

 

 

See IMPORTANT statement

 

heater is running

 

 

above

 

 

 

2.

Low fuel supply (propane/LP

2.

Refill supply tank

 

 

gas)

 

 

 

3.

Gas leak. See Warning

3.

Locate and correct all leaks

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 11)

 

 

 

 

 

Heater shuts off in use (ODS

1.

Not enough fresh air is avail-

1.

Open window and/or door for

operates)

 

able

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

3.

O D S / p i l o t i s p a r t i a l l y

3.

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 16)

 

 

 

 

 

Gas odor even when pilot knob

1.

Gas leak. See Warning

1.

Locate and correct all leaks

is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 11)

 

2.

Valve defective

2.

Replace valve

Gas odor during combustion

1.

Foreign matter between valve

 

 

and burner

 

2.

Gas leak. See Warning

 

 

statement at top of page

1.Take apart gas tubing and remove foreign matter

2.Locate and correct all leaks (see Checking Gas Connec- tions, page 11)

Moisture/condensation noticed

1. Not enough combustion/ven-

1. Refer to Fresh Air for Com-

on windows

tilation air

bustion and Ventilation re-

 

 

quirements (page 5)