TROUBLESHOOTING

Note: In normal operation, LED blinks once every two seconds; also, LED will be on for one second after every valid command received by the receiver/valve' these are not error codes.

Failure codes can occur anytime after the pilot burner is lit. Failure code timing is 1/4 second on, 1/2 second off.

Sequence is failure code followed by LED not blinking for four seconds.

In the event of multiple failure codes, the next failure code follows the previous failure code by approximately 3 seconds.

LED Failure Code

 

(No. of Blinks)

Service Action

 

 

8

Replace valve.

 

 

7

Confirm stepper motor

 

connection exists.

 

 

5

Confirm fan connection

 

exists and works.

 

 

3

Replace thermopiles.

 

 

2

Devicetoohot.Turnonfan

 

orifapplicable,openglass

 

doors.

1 short blink

Normal operation

 

 

LED Failure Codes and Service Action

WARNING:Turnoffandunplugheaterandletcoolbeforeservicing. Only a qualified service person should service and repair heater.

IMPORTANT: Valve system troubleshooting should only be accom- plished by a qualified service technician.

Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the "ON" position.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

 

 

Spark ignitor will not light pilot after repeated triggering of ig- nitor button

1.Defective ignitor (no spark at electrode)

2.Defective or misaligned electrode at pilot (spark at electrode)

3.Gas supply pressure errant

4.Pilot orifice plugged

1.Check for spark at electrode and pilot; if no spark and electrode wire is properly connected, replace ignitor

2.Using a match, light pilot. If pilot lights, turn off pilot and trigger the ignitor button again. If pilot lights, an improper gas mixture caused the bad lighting and a longer purge period is recommended. If pilot will not light, check gap at electrode and pilot - gap should be 1/8" to have a strong spark. If gap measures 1/8", replace pilot

3.Check inlet gas pressure. It should be within the limits as marked on the rating plate

4.Clean or replace pilot orifice

Pilot will not stay lit after care-

1. Defective pilot generator

1. Check pilot flame, it must

fully following the lighting

(thermocouple)

impinge on thermocouple

instructions

 

(see Figure 13, page 11).

 

 

Clean and/or adjust pilot for

 

 

maximum flame impingement

 

 

on thermocouple. Ensure that

 

 

the connection between the

 

 

valve and thermocouple are

 

 

tight and secure.

115481-01B

www.desatech.com

13

Page 13
Image 13
Design Dynamics HKE-24-RFN Troubleshooting, Observed Problem Possible Cause Remedy, No. of Blinks Service Action