DeVillbiss Air Power Company S2600 Problem Causecorrection, Water leaking at pump Pump Pulsates

Models: A08989 S2600

1 40
Download 40 pages 17.38 Kb
Page 18
Image 18

PROBLEM

CAUSECORRECTION

Will not draw detergent/ cleaning solution

Spray wand not in low pressure.

Filter on end of detergent injection system rinsing hose is clogged.

Screen on end of detergent injection system rinsing hose not in water

Detergent/cleaning solution too thick.

Pressure hose is too long

Detergent/cleaning solution build up in detergent injection system.

Hoses are not connected.

See How to Use Spray Wand paragraph in the Operation Section.

Clean filter.

Make sure end of detergent injection system rinsing hose is fully submerged into clean water.

Dilute detergent/cleaning solution. Detergent/cleaning solution should be the same consistency as water.

Lengthen water supply hose instead of high pressure hose.

Have parts cleaned or replaced by certified mechanic.

Make sure all hoses are connected at valve.

Detergent selection dial is in the

Turn detergent selection dial

down (off) position or pointed

toward tank being used.

toward the tank not being uses.

 

No or low pressure (after period of normal use)

Water leaking at gun/ spray wand connection

Water leaking at pump

Pump

Pulsates

Worn seal or packing Worn or obstructed valves. Worn unloader piston.

Worn or broken o-ring.

Loose hose connection.

Loose connections.

Piston packings worn.

Worn or broken o-rings.

Pump head or tubes damaged from freezing.

Nozzle obstructed.

Call: 1 866 474 6664

Call: 1 866 474 6664

Call: 1 866 474 6664

Check and replace.

Tighten.

Tighten.

Call: 1 866 474 6664

Call: 1 866 474 6664

Call: 1 866 474 6664

See Nozzle Cleaning paragraph in the Maintenance section for the correct procedure.

A08989

18- ENG

Page 18
Image 18
DeVillbiss Air Power Company S2600, A08989 Problem Causecorrection, Water leaking at pump Pump Pulsates