Electrical System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

 

 

Problem

 

 

Corrective Action

 

 

 

 

Will not turn on

 

No power

 

Check circuit breaker and/or GFCI

 

 

 

 

– in any mode

 

 

 

 

 

 

 

 

 

 

 

 

Turns on by itself

 

 

Normal automatic daily

 

 

No action required

 

 

 

 

 

 

 

 

power filtration, or anti-

 

 

 

 

 

 

 

 

 

 

 

 

freeze cycle

 

 

 

 

 

 

 

 

Light is out

 

Burned out bulb

 

Replace bulb

 

 

 

 

Pump shuts

 

 

1.

Automatic timer

 

 

1.

Push JETS pad again to start another cycle

 

 

 

 

down

 

 

 

has shut pump off

 

 

 

 

 

 

 

 

unexpectedly

 

2.

Motor over-heated

 

 

2. If pump(s) will not restart when JETS pad is pushed, call for service

 

 

 

 

while in use

 

 

 

 

 

 

 

 

 

 

 

 

and automatic

 

 

 

 

 

 

 

 

 

 

 

 

 

protective device

 

 

 

Make sure that the equipment panel vent area is not blocked. Vent blockage

 

 

 

 

 

 

 

 

 

has shut down

 

 

 

can cause serious damage to your equipment.

 

 

 

 

 

 

 

 

 

pump(s)

 

 

 

 

 

 

 

 

3 flashing LEDs

 

 

Possible sensor errors

 

 

1.

Check water level

 

 

 

 

appear on the

 

 

 

 

 

2.

Clean filter

 

 

 

 

Top Side Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If problem persists:

 

 

 

 

 

 

 

 

 

 

 

1.

Turn off power

 

 

 

 

 

 

 

 

 

 

 

2.

Restart the system

 

 

 

 

 

 

 

 

 

 

 

 

If problem persists:

 

 

 

 

 

 

 

 

 

 

 

 

 

Call for service

 

 

 

 

Spa lights always

 

Whenever the lights are

 

 

Because both lights are synchronized together, they always return to a “common

 

 

 

 

start in the

 

turned off they always

 

 

starting point” after they have been turned off for more than five seconds. This

 

 

 

 

default light

 

turn on in Color Fade

 

 

ensures that they will remain synchronized.

 

 

 

 

sequence

 

Fast mode

 

 

 

 

 

 

63