Dimension One Spas Sarena Bay manual Electrical System Cont, Water System, Symptom, Problem

Models: Sarena Bay

1 56
Download 56 pages 52.26 Kb
Page 54
Image 54
Electrical System (Cont)

2003 Sarena Bay

Export Owner’s Manual

Electrical System (Cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

 

 

Problem

 

 

Corrective Action

 

 

3 flashing LEDs

 

 

Possible sensor errors

 

 

1.

Check water level

 

 

appear on the

 

 

 

 

 

 

 

 

 

Top Side Control

 

 

 

 

2.

Clean filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If problem persists:

 

 

 

 

 

 

 

 

1.

Turn off power

 

 

 

 

 

 

 

 

2.

Restart the system

 

 

 

 

 

 

 

 

 

If problem persists:

 

 

 

 

 

 

 

 

 

 

Call for service

 

 

Spa lights always

 

Whenever the lights are

 

 

Because both lights are synchronized together, they always return to a “common

 

 

start in the

 

turned off they always

 

 

starting point” after they have been turned off for more than five seconds. This

 

 

default light

 

turn on in Color Fade

 

 

ensures that they will remain synchronized.

 

 

sequence

 

Fast mode

 

 

 

 

 

Water System

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

 

Problem

 

 

Corrective Action

 

 

Pulsating jets

 

Water level too low

 

 

Fill with water to the bottom of the OptiMountlocated next to the Skimmer

 

 

 

 

 

 

 

 

/Filter Basket.

 

 

No Jet Action,

 

1. Jets are turned off

 

 

1.

Turn jets on by turning jet face clockwise

 

 

or action is

 

2.

Diverter Valve

 

2.

Turn the Diverter Valve clockwise or counter clockwise

 

 

poor

 

 

 

 

 

 

turned

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Dirty Filter

 

 

3.

Clean Filter

 

 

 

 

4.

Air lock

 

4.

Loosen pump union to allow air to bleed

 

 

 

 

5.

Gate valve closed

 

 

5.

Open gate valve

 

 

The “Check

 

Possible sensor errors

 

1.

Check water level

 

 

Water

 

 

 

 

 

2.

Clean filter

 

 

Level…..”

 

 

 

 

 

 

 

scrolling

 

 

 

 

3.

If problem continues:

 

 

message and /or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 flashing

 

 

 

 

 

 

a.

Turn off power

 

 

L.E.D.s appear

 

 

 

 

 

 

b.

Restart the spa

 

 

on the display.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

If problem persists:

 

 

 

 

 

 

 

 

 

a.

Call your dealer for service

 

 

Fountain

 

The bottom of the

 

 

The water level in the spa is too high. Remove enough water to return the water

 

 

doesn’t drain

 

fountain has water that

 

 

level to slightly below the bottom of the OptiMountlocated adjacent to the

 

 

 

 

will not drain out.

 

 

Skimmer/Filter Basket.

 

 

 

 

 

 

 

 

 

 

 

 

48

Page 54
Image 54
Dimension One Spas Sarena Bay manual Electrical System Cont, Water System, Symptom, Problem, Corrective Action