5 - SYSTEM REPORTS
5.1
SYSTEM REPORTS
SYSTEM REPORTS
5.2 | OPN/CLOS | YES |
|
|
|
5.3 | ABORT | NO |
|
|
|
This section of the Programmer allows you to select the reports the XR10 sends to the receiver.
OPENING/CLOSING REPORTS
YES allows the panel to send opening/closing reports by user to the receiver.
ABORT REPORT
YES allows the panel to send an alarm abort report to the receiver any time an alarm report has also been sent and the Bell Cutoff time has not expired. See Bell Cutoff section 7.2.
The area must be disarmed and no alarmed zones can still be armed.
5.4
RESTORAL: YES
ZONE RESTORAL REPORTS
NO YES DISARM
This option allows you to specify whether the panel sends zone restoral reports and also when they'll be sent.
NO - Restoral reports are not sent by the panel.
YES - The panel always sends zone restoral reports at the time the zone restores from an alarm or trouble condition.
DISARM - The panel sends zone restoral reports when a zone that has restored from an alarm or trouble is disarmed.
5.5
BYPASS YES
BYPASS REPORTS
5.6
CODE CHG | YES |
|
|
YES allows the panel to send all zone bypass, reset, and force arm reports to the receiver. The bypass report includes the zone number, zone name, and the user number of the individual bypassing the zone.
CODE CHANGE REPORTS
5.7
AMBUSH NO
YES allows the panel to send all code additions, changes, and deletions to the receiver. The code change report includes the user number added or deleted and the user number of the individual making the change.
AMBUSH
YES allows an ambush report to be sent anytime user code number one is entered at a keypad. Selecting NO disables the ambush report and allows user code number one to operate the same as all other codes.
XR10 Programming Guide
2841 E. Industrial Drive Springfield, MO
8