Image 13
6 - SYSTEM OPTIONS

6 - SYSTEM OPTIONS

6.1

SYSTEM OPTIONS

SYSTEM OPTIONS

6.2

ALL/PRM YES

This section allows you to select system wide functions of the XR10 system.

ALL/PERIMETER

YES configures the panel as a Perimeter (Area 1) and Interior (Area 2) system.

NO configures the panel for Home/Sleep/Away operation. In addition to the Perimeter (Area 1) and Interior (Area 2) a third area, Bedrooms (Area 3) is created. Zones must be assigned to Bedrooms for the area to be active.

6.3

CLS CODE NO

CLOSING CODE

6.4ENTRY DLY 1: 30

ENTRY DLY 2: 60

6.5EXIT DELAY: 45

6.6

CRS ZONE TM:

0

 

 

 

6.7PWR FAIL HRS: 1

6.8

RST SBYP

YES

When YES is selected, a code number is required for system arming. If NO is selected, a code number is not required for system arming.

ENTRY DELAY 1

Enter the Entry Delay time for all Exit type zones programmed to use Entry Delay 1. When an armed Exit type zone is faulted, the keypad prewarn tone begins sounding and ENTER CODE: - displays on all keypads.

The area must be disarmed before the Entry Delay time expires or an alarm will occur on the entry zone. All Burglary type zones in all areas are delayed along with the Exit zone during the Entry Delay. Entry delay times can be from 1 to 250 seconds in one second increments.

Repeat the above for Entry Delay 2 if it is being used.

EXIT DELAY

Enter the Exit Delay time for all Exit type zones. When the system is armed, this Exit Delay time starts and all activity on Exit and Burglary zones is ignored until the Exit Delay expires. This delay countdown is displayed on the keypad for the user.

If an Exit type zone is in a bad condition at the end of the Exit Delay:

the alarm bell sounds for 15 seconds

an Exit Error report is sent to the alarm receiver

the bad Exit type zone is force armed

If any other zone is in a bad condition at the end of the Exit Delay, an alarm on that zone is indicated. The Exit Delay time can be from 1 to 250 seconds in one second increments.

Enter zero to disable the Exit Delay feature.

CROSS ZONE TIME

Enter the time allowed between zone faults. When a zone programmed for cross zoning faults, the panel begins counting down the Cross Zone Time you enter here. If the same zone or another zone faults within this time, an alarm report is sent to the receiver.

If the Cross Zone Time expires without the second zone fault, only a zone fault report from the first zone is sent to the receiver. The Cross Zone Time can be from 4 to 250 seconds in one second increments.

Enter zero to disable the Cross Zone Time feature.

POWER FAIL DELAY

This option allows you to delay the reporting of an AC power failure. When the AC power is off for the length of the programmed delay time, an AC power failure report is sent to the receiver. The delay time can be from 1 to 9 hours. Entering a zero sends the AC power failure report within 15 seconds.

RESET SWINGER BYPASS

When YES is selected, a swinger bypassed zone is reset if it remains in a normal condition for one hour after being bypassed. A report of the automatic reset is sent to the receiver if Bypass Reports has been selected as YES. See section 5.5.

XR10 Programming Guide