Napoleon Fireplaces BGD42CFN Using Rigid Vent Components, Vertical Venting Installation, flange

Models: BGD42CFN BGD36CFNTR BGD36CFGN

1 48
Download 48 pages 29.33 Kb
Page 22
Image 22
USING RIGID VENT COMPONENTS
FIGURE 63
FIGURE 61
BGD36CF SHOWN
INNER
VENT PIPE
FIGURE 62
AIR
TERMINAL
CONNECTOR
HIGH
TEMPERATURE SEALANT
EXHAUST VENT PIPE
AIR INTAKE
VENT PIPE

22

USING RIGID VENT COMPONENTS

HORIZONTAL AIR TERMINAL INSTALLATION

1.Move the fireplace into position. Measure the vent length required between terminal and fireplace taking into account the additional length needed for the finished wall surface and any 1¼" overlaps between venting components.

2.Apply high temperature sealant W573-0007 (not supplied) to the outer edge of the exhaust vent pipe of the fi replace. Attach the fi rst vent component and secure using 3 self tapping screws. Repeat using air intake vent pipe and seal using high temperature sealant W573-0002 (not supplied).

3.Holding the air terminal (lettering in an upright, readable posi- tion), insert into both vent pipes with a twisting motion to ensure that both the terminal sleeves engage into the vent pipes and sealant. Secure

the terminal to the

exterior wall and

 

ING

 

 

 

 

CAULK

 

 

 

make weather tight by

 

 

 

 

T

 

 

 

 

US

sealing with caulking

 

 

HA

 

 

EX

 

 

 

 

 

 

 

(not supplied).

ATTENTI

 

 

 

 

CAUTIONON-

CHAUD

 

 

 

-

 

 

 

HOT

 

 

 

The air terminal mounting

 

 

AIR

INTAKE

 

2” OVERLAP

VENT

PIPE

plate may be recessed into

 

HI-

 

 

 

SE

TEMP

 

the exterior wall or siding by

 

 

ALA

 

 

 

 

NT

 

 

 

 

 

 

1½", the depth of the return

 

#10 X 2”

 

 

 

 

SCREWS

 

 

 

flange.

 

FIGURE 60

EXTENDED HORIZONTAL AND CORNER

AIR TERMINAL INSTALLATION

1.Follow the instructions for "Horizontal Air Terminal Installations", items 1 to 3.

2.Continue adding components alternating inner and outer venting. Ensure that all exhaust vent-

ing and elbows have sufficient vent spacers attached and each component is securely fastened to the one prior. Attach the exhaust

telescopic sleeve to the vent run. Repeat using a air intake vent pipe telescopic sleeve. Secure and seal as before. To facilitate completion, attach exhaust and air intake vent pipe couplers to the air terminal.

3. Install the air terminal. See item 3 of the Horizontal Air Terminal Installation. Extend the

exhaust telescopic sleeve; connect to the air terminal assembly. Fasten with self tapping screws and seal. Repeat using the air intake vent pipe telescopic sleeve.

VERTICAL VENTING INSTALLATION

For safe and proper operation of the fireplace, follow the venting instructions exactly.

All inner exhaust and outer intake vent pipe joints may be sealed using either high temperature sealant W573-0002 or high temperature Mill Pac W573-0007 with the exception of the fireplace exhaust flue collar which must be sealed using Mill Pac (not supplied).

1.Move the fi replace into position.

2.Fasten the roof support to the roof using the screws provided. FIGURE 56. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suit- able to the authority having jurisdiction or the optional roof support.

3.Apply high temperature sealant W573-0002 (not supplied) to the outer edge of the inner end of the air terminal connector. Slip a coupler a minimum of 2" over the exhaust collar and secure using

3 screws.

4. Apply high temperature sealant to the outer edge of the of the outside pipe of the air terminal connector. Slip a coupler over the air intake collar and secure as before. Trim the air intake coupler even with the exhaust coupler end.

5. Thread the air terminal connector / pipe assembly down through the roof support and attach, ensuring that the air terminal will penetrate the roof a minimum 16" when fastened. If the attic space is tight, we recommend threading

the Wolf Steel vent pipe collar or equiva-

lent loosely onto the air terminal assembly as it is passed through the attic. The air terminal must be located vertically and plumb.

6.Remove nails from the shingles, above and to the sides of the chimney. Place the fl ashing over the air terminal and slide it underneath the sides and upper edge of the shingles. Ensure that the air terminal is properly centered within the fl ashing, giving a 3/4" margin all around. Fasten to the roof. Do NOT nail through the lower portion of the fl ashing. Make weather-tight by sealing with caulking. Where possible, cover the sides and top edges of the

fl ashing with roofi ng material.

7.Align the seams of the terminal and air terminal connector, place the terminal over the air terminal connector making sure the inner pipe goes into the hole in the terminal. Secure with screws provided.

8.Apply a heavy bead of weatherproof caulking 2" above the

ashing. Note: Maintain a minimum of 2" space between the air inlet base and the storm collar. Install the storm collar around the air terminal and slide down to the caulking. Tighten to ensure that a weather-tight seal between the air terminal and the collar is achieved.

9. Continue adding rigid venting sections, sealing and securing as above. Attach an exhaust telescopic sleeve to the last section of rigid piping. Secure with screws and seal. Repeat using an air intake telescopic sleeve.

10. REAR VENT APPLICATION: (BGD36CF(G) ONLY: Before attaching elbows to the collars on the back of the fireplace, 1½" will need to be trimmed off the exhaust pipe collar.)

Run a bead of high temperature sealant W573-0007 (not supplied) around the outside of the exhaust collar. Attach the exhaust elbow to the exhaust collar and secure with 3 screws. Run a bead of high temperature sealant W573-0002 (not supplied) around

the outside of the air intake collar. Attach the air intake elbow to the air intake collar and secure with 3 screws. Pull the exhaust

telescopic sleeve a minimum 2"

onto the elbow. Secure with 3 screws. Repeat with the air intake telescopic sleeve.

TOP VENT APPLICATION: Run a bead of high temperature seal- ant W573-0007 (not supplied) around the outside of the exhaust on the fi replace. Pull the exhaust telescopic sleeve a minimum of 2" onto the collar. Secure with 3 screws. Repeat with the air intake telescopic sleeve.

11.In the attic, slide the vent pipe collar down to cover up the open end of the vent pipe shield and tighten. This will prevent any ma- terials, such as insulation, from fi lling up the 1" air space around the pipe.

W415-0661 / C / 02.20.08

Page 22
Image 22
Napoleon Fireplaces BGD42CFN Using Rigid Vent Components, Vertical Venting Installation, Extended Horizontal And Corner