CLEARANCES

Design Guide

CLEARANCES

When Installed into a corner: 25"Clearances for Multiple Single Door Installations Min. to

130° Door Wall Swing

130°

2"

ZUG2, ZUGSS2 Unified Grille Panel Kit 15" Manual background

These units are equipped with a 2-position door stop. The factory set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted. Order WX14X99 door stop for precise settings between 90° and 130°.

When Installed into a corner:

Allow 25" for a full 130° door swing. Allow 15" for pan removal. Allow 4" min. clearance when door swing is adjusted to a 90° opening for pan access, but pan removal is restricted.

Clearances for Multiple Single Door Installations

In a side-by-side installation of a left and right door swing product, a 1" clearance between the units is required. Order ZUGSS2 Stainless Steel Unified Grille Panel Kit or ZUG2 Custom Panel Unified Grille Panel Kit for one continuous grille panel.

Clearances for two products installed side-by-side with the same (left or right) door swing

Allow 2" minimum clearance between the products

to prevent door swing interference. Order the WX14X99 adjustable door stop to reduce the factory set 130° door swing. Allow 15" minimum to a wall to achieve full drawer extension and pan removal.

NOTE: ZUG2 and ZUGSS2 Grille Panel Kit will NOT fit this installation.

5"

Clearances for two products installed side-by-side with right and left side hinges together

Allow 5" minimum between the two products to prevent one door from striking the other. Use the WX14X99 adjustable door stop to reduce the factory set 130° door swing and to allow pan removal.

NOTE: ZUG2 and ZUGSS2 Grille Panel Kit will NOT fit this installation.

ZUG2, ZUGSS2 Unified Grille Panel Kit

If you are installing two units, side by side, the installation space must be 71-1/2" wide.

Note: Additional cutout width may be required when side panels are used. Add side panel thickness

to the finished cutout to calculate rough-in width.

The water and electrical locations for each product must be located as shown.

A separate 115V, 60Hz., 15 or 20 amp power supply is recommended for each product.