FIGURE 119

34

Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the secur- ing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the fi rebox wall.

Attach the connectors from the black and red wires to the blower.

Attach and secure the vari- able speed switch using the nut provided. Plug the har- ness cord into the receptacle.

Note: To improve access to the variable speed control, we recom- mend bending the mounting bracket forward by approximately 10°.

The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, pre- venting it from making contact with moving or hot objects.

Drywall dust will penetrate into the blower bearings, causing irrepara- ble damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.

FIGURE 120

OPTIONAL FAN INSTALLATION

ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED IN- STALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1

CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL

ELECTRICAL CODE in the United States.

FIGURE 121

To safely install the fan, turn off the electricity fi rst.

If the fireplace was not previously equipped with a fan: route a grounded 2-wire, 60hz power cable to

the junction box. At this point, it must be strain relieved and insulated.

The wire harness provided in this

FIGURE 122

kit is a universal harness. When in-

 

stalled, ensure that any excess wire is

 

contained, preventing it from making

 

contact with moving or hot objects.

 

To ease installation of the fan, remove

the hinge screen and valve control door (lower louvres) from the base of the fi replace.

Position the vibration reducing pad into the clip and onto the threaded stud at the other end, piercing a hole into the pad. The fan assembly must be able to be positioned entirely onto the pad.

Slide the fan assembly past the controls and into the clip. Secure using the lock washer and nut provided.

Plug the harness cord into the receptacle.

GD36 THERMOSTATIC

SENSOR CONTROL

This optional kit is meant to be used only in conjunction with the GD65 Fan Kit, shown above, which may be ordered from your Wolf Steel / Napoleon® dealer.

With the thermostatic sensor option, the fan, when turned on, be- comes thermally activated, and will automatically run approximately 15-30 minutes after the fi replace has been lit and for approximately 30-45 minutes after the fi replace has been turned off.

Use of the fan increases the output of heat.

Unplug the power cord from the receptacle. Connect all wires as shown.

FIGURE 123

Attach and secure the sensor assembly bracket to the securing stud located next to the receptacle/junction box at the bottom left of the unit using the lock washer and wing nut. Ensure that the thermodisc touches the fi rebox wall.

Plug the power cord back into the receptacle.

When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot objects. FIGURE 124

W415-0661 / C / 02.20.08

Page 34
Image 34
Napoleon Fireplaces BGD42CFN, BGD36CFGN, BGD36CFNTR GD36 Thermostatic Sensor Control, Electrical Code in the United States