OPTIONAL BLOWER INSTALLATION

33

OPTIONAL BLOWER INSTALLATION

BGD36CF(G) ACCESSING THE BLOWER FIGURE 114

1.Remove the valve access door.

2.Open the main door.

3.Carefully remove the logs.

3a. (BGD36CFG) Carefully remove the glass and glass ember tray.

4.Remove the 7 screws illustrated in Fig. 112a and lift out the log support.

4a. (BGD36CFG) Remove the top defl ector and porcelain panels from the fi rebox. (See Figure 109).

FIGURE 112a

5.Remove the 8 perimeter screws as illustrated in Fig. 112a and lift out the burner base. (The gas line fl ex-connector should pro-

vide suffi cient move-

FIGURE 112bment to permit shifting the burner assembly

to the side).

6. Reverse procedure to re-assemble.

BGD42CF ACCESSING THE BLOWER

1.Remove the main door using the instructions on Pg #29.

2.Carefully remove the logs.

3.Remove the grate by lifting it off of the two securing pins.

4.Remove the 6 screws illustrated in Fig. 112b and lift out the log support. Be careful not to lose the spacers for the screws indicated.

FIGURE 113

SPACERS

5.Remove the 7 perimeter screws as illustrated in Fig. 113 and lift out the burner base. (The gas line fl ex-connector should provide suffi cient movement to permit shifting the burner assembly to the side).

6.Reverse procedure to re-assemble.

INSTALLING THE BLOWER

 

INSTALLATION TO BE

 

DONE BY A QUALI-

 

FIED INSTALLER and

 

must be electrically con-

 

nected and grounded in

 

accordance with local

 

codes. In the absence

 

of local codes, use

 

the current CSA C22.1

 

CA N A D I A N E L E C T R I C A L

FIGURE 116

CODE in Canada or the

ANSI/NFPA 70 NATIONAL

 

ELECTRICAL CODE in the

 

United States

 

FIGURE 117

If the fireplace was not

 

previously equipped with

 

a blower: route a grounded

 

2-wire, 60hz power cable

 

to the receptacle / junction

 

box. At this point, it must

 

be strain relieved and in-

 

sulated.

 

Because the blower is thermally activated, when

turned on, it will automatically start approximately 10 minutes after lighting the fireplace and will run for approximately 30-45 minutes after the fireplace has been turned off. Use of the fan increases the output of heat.

The three slots on the blower mounting bracket allow ease of adjust- ment when attaching the blower. For a quiet running blower, do not allow the assembly to sit on the fi rebox base.

Slide the vibration reducing pad (A) into the clip (C) and up against the threaded stud (B) at the other end. The blower must be able to be positioned entirely onto the pad.

To ease installation of the blower, remove the hinge screen and valve control door (lower louvres) from the base of the fi replace.

Tilt the blower onto its side. Slide it past the controls and into the clip

(C). Secure to the threaded stud using the lock washer and wing nut provided. Ensure that the blower does not touch the fi replace base or the fi rebox.

FIGURE 118a
FIGURE 118b

B

AC

W415-0661 / C / 02.20.08