BGD36CFG LIGHT SWITCH / WIRING DIAGRAM

36

BGD36CFG LIGHT SWITCH / WIRING DIAGRAM

A wall switch must be installed in a convenient location for the light operation.

The recommended maximum lead length depends on wire size:

WIRE SIZE

MAX. LENGTH

14 gauge

100 feet

16 gauge

60 feet

18 gauge

40 feet

A 20’ length of millivolt wire is connected to the gas valve for the light wall switch. However if a greater length is required route 2- strand (solid core) wire through the electrical hole located at the bottom left side of the unit.